Contamination and Release of Nanomaterials Associated with the Use of Personal Protective Clothing.

Introduction: We investigated nanomaterial release associated with the contamination of protective clothing during manipulation of clothing fabrics contaminated with nanoparticles. Nanomaterials, when released as airborne nanoparticles, can cause inhalation exposure which is the route of exposure of...

Descripción completa

Detalles Bibliográficos
Publicado en:Annals of Occupational Hygiene Vol. 59; no. 4; pp. 491 - 504
Autor principal: Su-Jung Tsai, Candace
Formato: pictorial research tables/charts Journal Article
Publicado: Oxford University Press / USA May2015
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=103196257&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 103196257
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        00034878
        JQ4
      jtl: Annals of Occupational Hygiene
      issn: 00034878
      maglogo: N
    pubinfo:
      dt: May2015
      vid: 59
      iid: 4
      pid: 622
      pub: Oxford University Press / USA
    artinfo:
      ui:
        103196257
        109798838
        109798838
        10.1093/annhyg/meu111
        103196257
      ppf: 491
      ppct: 13
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Contamination and Release of Nanomaterials Associated with the Use of Personal Protective Clothing.
      aug:
        au: Su-Jung Tsai, Candace
        affil: Birck Nanotechnology Center, Purdue University, 1205 West State Street, West Lafayette, IN 47907, USA
      sug:
        subj:
          Protective Clothing Evaluation
          Equipment Contamination Analysis
          Nanostructures Standards
          Air Pollutants
          Aerosols
          Occupational Exposure
          In Vitro Studies
          Microscopy, Electron, Scanning
          Spectrum Analysis
          Comparative Studies
          Laboratories
          T-Tests
          Descriptive Statistics
          Data Analysis Software
          Funding Source
      ab: Introduction: We investigated nanomaterial release associated with the contamination of protective clothing during manipulation of clothing fabrics contaminated with nanoparticles. Nanomaterials, when released as airborne nanoparticles, can cause inhalation exposure which is the route of exposure of most concern to cause adverse health effects. Measurement of such nanparticle re-suspension has not yet been conducted. Protective clothing can be contaminated with airborne nanoparticles during handling and operating processes, typically on the arms and front of the body. The contaminated clothing could release nanoparticles in the general room while performing other activities and manipulating the clothing after work. Methods: The exposures associated with three different fabric materials of contaminated laboratory coats (cotton, polyester, and Tyvek), including the magnitude of contamination and particle release, were investigated in this study by measuring the number concentration increase and the weight change on fabric pieces. This study simulated real life occupational exposure scenarios and was performed in both regular and clean room environments to investigate the effect of background aerosols on the measurements. Concentration were measured using particle spectrometers for diameters from 10nm to 10 µm. Collected aerosol particles and contaminated fabric surfaces were characterized using scanning electron microscopy (SEM), transmission electron microscopy (TEM), and elemental composition analysis. Results: The magnitude of particle release from contaminated lab coat fabric was found to vary by the type of fabric material; cotton fabric showed the highest level of contamination and particle release, followed by Tyvek and polyester fabrics. The polyester lab coat material was found to have the lowest particle release to deposition (R/D) ratio. The particle release number concentrations were in a range of 768-119 particles cm-3 and 586-187 particles cm-3 in regular and clean rooms, respectively. Multiple peaks were observed in the number concentration distribution data, with particle diameters peaking at 40-50 and 100-300nm. Conclusions: The SEM analysis of the contaminated fabric surface found test particles and other environmental particles. The elemental composition analysis presented detectable response to the studied alumina oxide particles. The laboratory coat primarily made of cotton woven material is not recommended for worker protection against nanoparticle exposure because of the highest particle contamination and release ability. In addition, the result demonstrated that a well-controlled (clean- room) environment is critical to investigate the factors affecting nanoparticle interaction with protective clothing.
      pubtype: Academic Journal
      doctype:
        pictorial
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N