Diagnostic accuracy of dual-echo (in- and opposed-phase) T1-weighted gradient recalled echo for detection and grading of hepatic iron using quantitative and visual assessment.

Objectives: Detection and quantification of hepatic iron with dual-echo gradient recalled echo (GRE) has been proposed as a rapid alternative to other magnetic resonance imaging (MRI) techniques. Co-existing steatosis and T1 weighting are limitations. This study assesses the accuracy of routine dual...

Descripción completa

Detalles Bibliográficos
Publicado en:European Radiology Vol. 24; no. 7; pp. 1437 - 1446
Autores principales: Schieda, Nicola, Ramanathan, Subramaniyan, Ryan, John, Khanna, Maneesh, Virmani, Vivek, Avruch, Leonard
Formato: research Journal Article
Publicado: Springer Nature Jul2014
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=103827362&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 103827362
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        09387994
        NPH
      jtl: European Radiology
      issn: 09387994
      maglogo: N
    pubinfo:
      dt: Jul2014
      vid: 24
      iid: 7
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        103827362
        NLM24788037
        2012607284
        10.1007/s00330-014-3170-5
        NLM24788037
        103827362
      ppf: 1437
      ppct: 9
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Diagnostic accuracy of dual-echo (in- and opposed-phase) T1-weighted gradient recalled echo for detection and grading of hepatic iron using quantitative and visual assessment.
      aug:
        au:
          Schieda, Nicola
          Ramanathan, Subramaniyan
          Ryan, John
          Khanna, Maneesh
          Virmani, Vivek
          Avruch, Leonard
        affil: The Ottawa Hospital, The University of Ottawa, 1053 Carling Avenue; , Ottawa, Ontario, Canada, K1Y 4E9, nschieda@toh.on.ca.
      sug:
        subj:
          Magnetic Resonance Imaging Methods
          Fatty Liver Diagnosis
          Iron Analysis
          Iron Overload Diagnosis
          Liver
          Adolescence
          Adult
          Aged
          Aged, 80 and Over
          Fatty Liver Metabolism
          Female
          Prospective Studies
          Human
          Iron Overload Metabolism
          Liver Pathology
          Male
          Middle Age
          Reproducibility of Results
          Retrospective Design
          Young Adult
          Adolescent: 13-18 years
          Adult: 19-44 years
          Aged: 65+ years
          Aged, 80 & over
          Middle Aged: 45-64 years
          Female
          Male
      ab: Objectives: Detection and quantification of hepatic iron with dual-echo gradient recalled echo (GRE) has been proposed as a rapid alternative to other magnetic resonance imaging (MRI) techniques. Co-existing steatosis and T1 weighting are limitations. This study assesses the accuracy of routine dual-echo GRE.Methodology: Between 2010 and 2013, 109 consecutive patients underwent multi-echo (ME) MRI and dual-echo GRE for quantification of hepatic iron. Liver iron concentration (LIC) was calculated from ME-MRI. Relative signal intensity (RSI) and fat signal fraction (FSF) were calculated from dual-echo GRE. Four radiologists subjectively evaluated dual-echo GRE (±subtraction). Diagnostic accuracy was compared between techniques and correlated with biopsy using Fisher's exact test, Spearman correlation and regression.Results: The sensitivity of visual detection of iron ranged from 48 to 55%. Subtraction did not increase sensitivity (p < 0.001). Inter-observer variability was substantial (κ = 0.72). The specificity of visual detection of iron approached 100% with false-positive diagnoses observed using subtraction. LIC showed a higher correlation with histopathological iron grade (r = 0.94, p < 0.001) compared with RSI (r = 0.65, p = 0.02). Univariate regression showed an association between RSI and LIC (B = 0.98, p < 0.001, CI 0.73-1.23); however, the association was not significant with multi-variate regression including FSF (p = 0.28).Conclusions: Dual-echo GRE has low sensitivity for hepatic iron. Subtraction imaging can result in false-positive diagnoses.Key Points: • Routine liver MRI studies cannot effectively screen patients for iron overload. • Concomitant hepatic steatosis and iron limits diagnostic accuracy of routine liver MRI. • Dual-echo GRE subtraction imaging causes false-positive diagnoses of iron overload. • Dedicated MRI techniques should be used to diagnose and quantify iron overload.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N