Workflow Analysis Comparing Manual and Automated Specimen Processing for Mass Spectrometry–Based Vitamin D Testing.
Objective: To quantify the benefits of automating specimen extraction in terms of specimen-preparation times and labor usage. Methods: We used workflow modeling and time-motion studies to compare manual and automated solid-phase extraction methods to prepare specimens for a mass spectrometry–based v...
| Published in: | Laboratory Medicine Vol. 45; no. 4; pp. 361 - 368 |
|---|---|
| Main Authors: | , , , |
| Format: | research tables/charts Journal Article |
| Published: |
Oxford University Press / USA
Fall2014
|
| Online Access: | View this record in EBSCOhost |
| fields | @attributes: recordID: 1 pdfLink: plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=103918337&site=ehost-live header: @attributes: shortDbName: ccm uiTerm: 103918337 longDbName: CINAHL Complete uiTag: AN controlInfo: bkinfo: dissinfo: jinfo: jid: 00075027 4CY jtl: Laboratory Medicine issn: 00075027 maglogo: N pubinfo: dt: Fall2014 vid: 45 iid: 4 pid: 10398 pub: Oxford University Press / USA artinfo: ui: 103918337 99533157 10.1309/LMZL47EN6KDODMXJ NLM25316669 103918337 ppf: 361 ppct: 7 formats: fmt: @attributes: type: P tig: atl: Workflow Analysis Comparing Manual and Automated Specimen Processing for Mass Spectrometry–Based Vitamin D Testing. aug: au: Hermes Tacker, Danyel Topardo, Joyce Mahaffey, Carole Perrotta, Peter L. affil: Clinical Laboratory, Department of Pathology, West Virginia University Hospital, Morgantown, West Virginia sug: subj: Vitamin D Analysis Automation, Laboratory Specimen Handling Methods Task Performance and Analysis Mass Spectrometry Chromatography, Liquid Time and Motion Studies Data Analysis Software P-Value T-Tests Human ab: Objective: To quantify the benefits of automating specimen extraction in terms of specimen-preparation times and labor usage. Methods: We used workflow modeling and time-motion studies to compare manual and automated solid-phase extraction methods to prepare specimens for a mass spectrometry–based vitamin D assay. We processed 20 batches, that included 5 to 90 specimens each, with both methods in parallel and randomly over a 4-week period. Technologist discomfort/fatigue was subjectively measured. Results: Batch preparation time, per-specimen processing time, and labor requirements were significantly lower for all batch sizes on the Tecan Freedom EVO 150 robotic liquid-handling system (EVO). Technologist fatigue was significant when batch sizes reached 60 specimens. Cycle times were more uniform on the EVO. Automation provided as many as 85 minutes of useable technologist idle time for the 90-specimen batch. Conclusions: Automated specimen preparation should be considered when batch sizes reach 35 to 40 specimens per day. pubtype: Academic Journal doctype: research tables/charts Journal Article ougenre: Article language: English refInfo: holdings: @attributes: islocal: N |
|---|