Measuring hepatic functional reserve using low temporal resolution Gd-EOB-DTPA dynamic contrast-enhanced MRI: a preliminary study comparing galactosyl human serum albumin scintigraphy with indocyanine green retention.

Objective: To investigate if tracer kinetic modelling of low temporal resolution dynamic contrast-enhanced (DCE) MRI with Gd-EOB-DTPA could replace technetium-99 m galactosyl human serum albumin (GSA) single positron emission computed tomography (SPECT) and indocyanine green (ICG) retention for the...

Descripción completa

Detalles Bibliográficos
Publicado en:European Radiology Vol. 24; no. 1; pp. 112 - 120
Autores principales: Saito, Kazuhiro, Ledsam, Joseph, Sourbron, Steven, Hashimoto, Tsuyoshi, Araki, Yoichi, Akata, Soichi, Tokuuye, Koichi
Formato: research Journal Article
Publicado: Springer Nature Jan2014
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=103997878&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 103997878
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        09387994
        NPH
      jtl: European Radiology
      issn: 09387994
      maglogo: N
    pubinfo:
      dt: Jan2014
      vid: 24
      iid: 1
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        103997878
        NLM23949726
        2012436905
        10.1007/s00330-013-2983-y
        NLM23949726
        103997878
      ppf: 112
      ppct: 8
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Measuring hepatic functional reserve using low temporal resolution Gd-EOB-DTPA dynamic contrast-enhanced MRI: a preliminary study comparing galactosyl human serum albumin scintigraphy with indocyanine green retention.
      aug:
        au:
          Saito, Kazuhiro
          Ledsam, Joseph
          Sourbron, Steven
          Hashimoto, Tsuyoshi
          Araki, Yoichi
          Akata, Soichi
          Tokuuye, Koichi
        affil: Department of Radiology, Tokyo Medical University, 6-7-1 Nishi-Shinjuku, Shinjuku-ku, Tokyo, Japan, saito-k@tokyo-med.ac.jp.
      sug:
        subj:
          Albumins Diagnostic Use
          Contrast Media Diagnostic Use
          Indoles Diagnostic Use
          Liver Neoplasms Diagnosis
          Magnetic Resonance Imaging Methods
          Tomography, Emission-Computed, Single-Photon Methods
          Aged
          Dyes Diagnostic Use
          Female
          Hepatectomy
          Human
          Liver Function Tests
          Liver Neoplasms Metabolism
          Liver Neoplasms Surgery
          Liver Pathology
          Liver Radiography
          Male
          Prospective Studies
          Radiopharmaceuticals Diagnostic Use
          Reproducibility of Results
          Retrospective Design
          Aged: 65+ years
          Female
          Male
      ab: Objective: To investigate if tracer kinetic modelling of low temporal resolution dynamic contrast-enhanced (DCE) MRI with Gd-EOB-DTPA could replace technetium-99 m galactosyl human serum albumin (GSA) single positron emission computed tomography (SPECT) and indocyanine green (ICG) retention for the measurement of liver functional reserve.Methods: Twenty eight patients awaiting liver resection for various cancers were included in this retrospective study that was approved by the institutional review board. The Gd-EOB-DTPA MRI sequence acquired five images: unenhanced, double arterial phase, portal phase, and 4 min after injection. Intracellular contrast uptake rate (UR) and extracellular volume (Ve) were calculated from DCE-MRI, along with the ratio of GSA radioactivity of liver to heart-plus-liver and per cent of cumulative uptake from 15-16 min (LHL15 and LU15, respectively) from GSA-scintigraphy. ICG retention at 15 min, Child-Pugh cirrhosis score (CPS) and postoperative Inuyama fibrosis criteria were also recorded. Statistical analysis was with Spearman rank correlation analysis.Results: Comparing MRI parameters with the reference methods, significant correlations were obtained for UR and LHL15, LU15, ICG15 (all 0.4-0.6, P < 0.05); UR and CPS (-0.64, P < 0.001); Ve and Inuyama (0.44, P < 0.05).Conclusion: Measures of liver function obtained by routine Gd-EOB-DTPA DCE-MRI with tracer kinetic modelling may provide a suitable method for the evaluation of liver functional reserve.Key Points: • Magnetic resonance imaging (MRI) provides new methods of measuring hepatic functional reserve. • DCE-MRI with Gd-EOB-DTPA offers the possibility of replacing scintigraphy. • The analysis method can be used for preoperative liver function evaluation.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N