Impact of implementing smart infusion pumps in a pediatric intensive care unit.

Purpose. The impact of smart infusion pumps on the interception of errors in the programming of i.v. drug administrations on a pediatric intensive care unit (PICU) is investigated. Methods. A prospective observational intervention study was conducted in the PICU of a hospital in Madrid, Spain, to es...

Descripción completa

Detalles Bibliográficos
Publicado en:American Journal of Health-System Pharmacy Vol. 70; no. 21; pp. 1897 - 1907
Autores principales: Manrique-Rodríguez, Silvia, Sánchez-Galindo, Amelia C., López-Herce, Jesús, Calleja-Hernández, Miguel Ãngel, Martínez-Martínez, Fernando, Iglesias-Peinado, Irene, Carrillo-Ãlvarez, Ãngel, Sanjurjo Sáez, María, Fernández-Llamazares, Cecilia M.
Formato: research tables/charts Journal Article
Publicado: Oxford University Press / USA 11/1/2013
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=104144173&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 104144173
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        10792082
        1X3
      jtl: American Journal of Health-System Pharmacy
      issn: 10792082
      maglogo: N
    pubinfo:
      dt: 11/1/2013
      vid: 70
      iid: 21
      pid: 622
      pub: Oxford University Press / USA
    artinfo:
      ui:
        104144173
        91282817
        10.2146/ajhp120767
        NLM24128965
        104144173
      ppf: 1897
      ppct: 10
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Impact of implementing smart infusion pumps in a pediatric intensive care unit.
      aug:
        au:
          Manrique-Rodríguez, Silvia
          Sánchez-Galindo, Amelia C.
          López-Herce, Jesús
          Calleja-Hernández, Miguel Ãngel
          Martínez-Martínez, Fernando
          Iglesias-Peinado, Irene
          Carrillo-Ãlvarez, Ãngel
          Sanjurjo Sáez, María
          Fernández-Llamazares, Cecilia M.
        affil: Clinical Hospital Pharmacist, Pediatric Intensive Care Unit, Hospital General Universitario Gregorio Marañón, Madrid, Spain
      sug:
        subj:
          Intensive Care Units, Pediatric
          Infusion Pumps Utilization
          Medication Errors Prevention and Control
          Severity of Injury Classification
          Human
          Prospective Studies
          Observational Methods
          Spain
          Descriptive Statistics
          Data Analysis Software
          kappa Statistic
          Chi Square Test
          Physicians
          Pharmacists
          Nurses
      ab: Purpose. The impact of smart infusion pumps on the interception of errors in the programming of i.v. drug administrations on a pediatric intensive care unit (PICU) is investigated. Methods. A prospective observational intervention study was conducted in the PICU of a hospital in Madrid, Spain, to estimate the patient safety benefits resulting from the implementation of smart pump technology (Alaris System, CareFusion, San Diego, CA). A systematic analysis of data stored by the devices during the designated study period (January 2010-June 2011) was conducted using the system software (Guardrails CQI Event Reporter, CareFusion). The severity of intercepted errors was independently classified by a group of four clinical pharmacists and a group of four intensive care pediatricians; analyses of intragroup and intergroup agreement in perceptions of severity were performed. Results. During the 17-month study period, the overall rate of user compliance with the safety software was 78%. The use of smart pump technology resulted in the interception of 92 programming errors, 84% of which involved analgesics, antiinfectives, inotropes, and sedatives. About 97% of the errors resulted from user programming of doses or infusion rates above the hard limits defined in the smart pump drug library. The potential consequences of the intercepted errors were considered to be of moderate, serious, or catastrophic severity in 49% of cases. Conclusion. The use of smart pumps in a PICU improved patient safety by enabling the interception of infusion programming errors that posed the potential for severe injury to pediatric patients.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N