The Effects of Abnormal Blood Pressure on Arterial Sampler Filling Times.

BACKGROUND: Sampler filling time begins with the initial flash of blood in the needle hub until the preset sampler volume is obtained. Previous studies have shown statistically significant differences between arterial and venous sampler filling times, but included only a few subjects with abnormal b...

Full description

Bibliographic Details
Published in:Respiratory Care Vol. 58; no. 11; pp. 1907 - 1911
Main Authors: Cortes, Aaron L., Dalessandro, Chelsea M., Glade, Tina M., Shirdon, Sophia A. F., Uhlir, Jen J., Douce, F. Herbert
Format: research tables/charts Journal Article
Published: Mary Ann Liebert, Inc. Nov2013
Online Access:View this record in EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=104148073&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 104148073
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        00201324
        4GG
      jtl: Respiratory Care
      issn: 00201324
      maglogo: N
    pubinfo:
      dt: Nov2013
      vid: 58
      iid: 11
      pid: 1365
      pub: Mary Ann Liebert, Inc.
      place: New Rochelle, New York
    artinfo:
      ui:
        104148073
        91620100
        10.4187/respcare.02339
        NLM23592788
        104148073
      ppf: 1907
      ppct: 4
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: The Effects of Abnormal Blood Pressure on Arterial Sampler Filling Times.
      aug:
        au:
          Cortes, Aaron L.
          Dalessandro, Chelsea M.
          Glade, Tina M.
          Shirdon, Sophia A. F.
          Uhlir, Jen J.
          Douce, F. Herbert
        affil: Respiratory Therapy Division, School of Health and Rehabilitation Sciences, Ohio State University, Columbus, Ohio
      sug:
        subj:
          Blood Pressure Standards
          Arterial Pressure Standards
          Arterial Puncture
          Venipuncture
          Blood Gas Analysis Methods
          Time
          Human
          Descriptive Statistics
          Comparative Studies
          Correlational Studies
          Ohio
          Academic Medical Centers
          Data Analysis Software
          Pearson's Correlation Coefficient
      ab: BACKGROUND: Sampler filling time begins with the initial flash of blood in the needle hub until the preset sampler volume is obtained. Previous studies have shown statistically significant differences between arterial and venous sampler filling times, but included only a few subjects with abnormal blood pressures. OBJECTIVE: To determine whether the time required to fill a vented arterial sampler is an accurate indication of a successful arterial blood sample in adults with abnormal blood pressure. We hypothesized that mean arterial pressure and arterial sampler filling time would have a negative correlation, and that venous sampler filling time would be significantly longer than arterial filling time. METHODS: We studied 40 subjects: 25 arterial subjects, and 15venous subjects. The arterial subjects included 3 groups: hypertensive, hypotensive, or normal. During the arterial and venipuncture procedures, we measured sampler filling time and recorded blood volume. The PO2 of the samples was measured. Additionally, blood pressure and SpO2 were measured in the arterial group. RESULTS: The mean sampler filling time was 220.4 s/mL for the venous group, and 18.1 s/mL for all 3 arterial groups combined. There were significant differences between each mean arterial sampler filling rate and mean venous filling rate (P < .001). There were no significant differences in mean sampler filling rate between the arterial subgroups (P > .99). The correlation between mean arterial pressure and filling rates was 0.06 (P = .38). CONCLUSIONS: There is a significant difference between arterial and venous filling rates. There was no relationship between filling time and abnormal mean arterial pressure. Regardless of the arterial pressure, the arterial sampler filling time can be used as an indicator of a successful arterial puncture at the bedside.