Development of a Computer-Adaptive Physical Function Instrument for Social Security Administration Disability Determination.

Abstract: Objectives: To develop and test an instrument to assess physical function for Social Security Administration (SSA) disability programs, the SSA-Physical Function (SSA-PF) instrument. Item response theory (IRT) analyses were used to (1) create a calibrated item bank for each of the factors...

Full description

Bibliographic Details
Published in:Archives of Physical Medicine & Rehabilitation Vol. 94; no. 9; pp. 1661 - 1670
Main Authors: Ni, Pengsheng, McDonough, Christine M., Jette, Alan M., Bogusz, Kara, Marfeo, Elizabeth E., Rasch, Elizabeth K., Brandt, Diane E., Meterko, Mark, Haley, Stephen M., Chan, Leighton
Format: research Journal Article
Published: W B Saunders Sep2013
Online Access:View this record in EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=104216414&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 104216414
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        00039993
        1XL
      jtl: Archives of Physical Medicine & Rehabilitation
      issn: 00039993
      maglogo: N
    pubinfo:
      dt: Sep2013
      vid: 94
      iid: 9
      pid: 1351
      pub: W B Saunders
      place: Philadelphia, Pennsylvania
    artinfo:
      ui:
        104216414
        89976871
        10.1016/j.apmr.2013.03.021
        NLM23578594
        104216414
      ppf: 1661
      ppct: 9
      formats:
      tig:
        atl: Development of a Computer-Adaptive Physical Function Instrument for Social Security Administration Disability Determination.
      aug:
        au:
          Ni, Pengsheng
          McDonough, Christine M.
          Jette, Alan M.
          Bogusz, Kara
          Marfeo, Elizabeth E.
          Rasch, Elizabeth K.
          Brandt, Diane E.
          Meterko, Mark
          Haley, Stephen M.
          Chan, Leighton
        affil: Department of Health Policy and Management, The Health and Disability Research Institute, School of Public Health, Boston University Medical Campus, Boston, MA
      sug:
        subj:
          Disability Evaluation Methods
          Instrument Construction
          Computerized Adaptive Testing
          Instrument Validation
          Clinical Assessment Tools Evaluation
          Insurance, Disability
          United States Social Security Administration
          Functional Assessment Methods
          Psychometrics
          Health Status Indicators
          Clinical Assessment Tools
          Cross Sectional Studies
          Surveys
          Validation Studies
          Questionnaires
          Human
          Funding Source
      ab: Abstract: Objectives: To develop and test an instrument to assess physical function for Social Security Administration (SSA) disability programs, the SSA-Physical Function (SSA-PF) instrument. Item response theory (IRT) analyses were used to (1) create a calibrated item bank for each of the factors identified in prior factor analyses, (2) assess the fit of the items within each scale, (3) develop separate computer-adaptive testing (CAT) instruments for each scale, and (4) conduct initial psychometric testing. Design: Cross-sectional data collection; IRT analyses; CAT simulation. Setting: Telephone and Internet survey. Participants: Two samples: SSA claimants (n=1017) and adults from the U.S. general population (n=999). Interventions: None. Main Outcome Measures: Model fit statistics, correlation, and reliability coefficients. Results: IRT analyses resulted in 5 unidimensional SSA-PF scales: Changing & Maintaining Body Position, Whole Body Mobility, Upper Body Function, Upper Extremity Fine Motor, and Wheelchair Mobility for a total of 102 items. High CAT accuracy was demonstrated by strong correlations between simulated CAT scores and those from the full item banks. On comparing the simulated CATs with the full item banks, very little loss of reliability or precision was noted, except at the lower and upper ranges of each scale. No difference in response patterns by age or sex was noted. The distributions of claimant scores were shifted to the lower end of each scale compared with those of a sample of U.S. adults. Conclusions: The SSA-PF instrument contributes important new methodology for measuring the physical function of adults applying to the SSA disability programs. Initial evaluation revealed that the SSA-PF instrument achieved considerable breadth of coverage in each content domain and demonstrated noteworthy psychometric properties.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N