Validation of Omron RS8, RS6, and RS3 home blood pressure monitoring devices, in accordance with the European Society of Hypertension International Protocol revision 2010.
Background: Allowing patients to measure their blood pressure at home is recognized as being of clinical value. However, it is not known how often these measurements are taken correctly. Blood pressure monitors for home use fall into two types based on the position of the cuff, ie, at the upper arm...
| Publicado en: | Vascular Health & Risk Management Vol. 9; pp. 265 - 273 |
|---|---|
| Autores principales: | , , |
| Formato: | research Journal Article |
| Publicado: |
Dove Medical Press Ltd
2013
|
| Acceso en línea: | Ver este registro en EBSCOhost |
| fields | @attributes: recordID: 1 pdfLink: plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=104221250&site=ehost-live header: @attributes: shortDbName: ccm uiTerm: 104221250 longDbName: CINAHL Complete uiTag: AN controlInfo: bkinfo: dissinfo: jinfo: jid: 11766344 6BXM jtl: Vascular Health & Risk Management issn: 11766344 maglogo: N pubinfo: dt: 2013 vid: 9 pid: 45064 pub: Dove Medical Press Ltd place: Auckland, <Blank> artinfo: ui: 104221250 104221250 NLM23745050 2012242023 10.2147/VHRM.S44569 NLM23745050 PMC3671796 104221250 ppf: 265 ppct: 8 formats: fmt: @attributes: type: P tig: atl: Validation of Omron RS8, RS6, and RS3 home blood pressure monitoring devices, in accordance with the European Society of Hypertension International Protocol revision 2010. aug: au: Takahashi, Hakuo Yoshika, Masamichi Yokoi, Toyohiko affil: Department of Clinical Sciences and Laboratory Medicine, Kansai Medical University, Hirakata, Osaka, Japan. sug: subj: Blood Pressure Drug Effects Blood Pressure Monitoring, Ambulatory Equipment and Supplies Hypertension Diagnosis Wrist Blood Supply Adult Aged Antihypertensive Agents Therapeutic Use Blood Pressure Monitoring, Ambulatory Standards Calibration Equipment Design Female Guideline Adherence Human Hypertension Drug Therapy Hypertension Physiopathology Japan Male Middle Age Observer Bias Practice Guidelines Predictive Value of Tests Reproducibility of Results Sphygmomanometers Adult: 19-44 years Aged: 65+ years Middle Aged: 45-64 years Female Male ab: Background: Allowing patients to measure their blood pressure at home is recognized as being of clinical value. However, it is not known how often these measurements are taken correctly. Blood pressure monitors for home use fall into two types based on the position of the cuff, ie, at the upper arm or the wrist. The latter is particularly convenient, as measurements can be taken fully clothed. This study aimed to evaluate the performance of the wrist-type blood pressure monitors Omron RS8 (HEM-6310F-E), Omron RS6 (HEM-6221-E), and Omron RS3 (HEM-6130-E).Methods: A team of three trained doctors validated the performance of these devices by comparing the measurements obtained from these devices with those taken using a standard mercury sphygmomanometer. All the devices met the validation requirements of the European Society of Hypertension International Protocol revision 2010.Results: The difference in blood pressure readings between the tested device and the standard mercury sphygmomanometer was within 3 mmHg, which is acceptable according to the European Society of Hypertension guidelines.Conclusion: All the home devices tested were found to be suitable for measuring blood pressure at home because their performance fulfilled the requirement of the guidelines. pubtype: Academic Journal doctype: research Journal Article ougenre: Article language: English refInfo: holdings: @attributes: islocal: N |
|---|