Simulated required accuracy of image registration tools for targeting high-grade cancer components with prostate biopsies.

Objectives: To estimate the required spatial alignment accuracy for correctly grading 95 % of peripheral zone (PZ) prostate cancers using a system for multiparametric magnetic resonance (MR)-guided ultrasound (US) biopsies.Methods: PZ prostate tumours were retrospectively annotated on multiparametri...

Full description

Bibliographic Details
Published in:European Radiology Vol. 23; no. 5; pp. 1401 - 1408
Main Authors: van de Ven, Wendy J M, Hulsbergen-van de Kaa, Christina A, Hambrock, Thomas, Barentsz, Jelle O, Huisman, Henkjan J
Format: research Journal Article
Published: Springer Nature May2013
Online Access:View this record in EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=104269968&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 104269968
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        09387994
        NPH
      jtl: European Radiology
      issn: 09387994
      maglogo: N
    pubinfo:
      dt: May2013
      vid: 23
      iid: 5
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        104269968
        86879570
        NLM23138386
        2012081812
        10.1007/s00330-012-2701-1
        NLM23138386
        104269968
      ppf: 1401
      ppct: 7
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: Simulated required accuracy of image registration tools for targeting high-grade cancer components with prostate biopsies.
      aug:
        au:
          van de Ven, Wendy J M
          Hulsbergen-van de Kaa, Christina A
          Hambrock, Thomas
          Barentsz, Jelle O
          Huisman, Henkjan J
        affil: Department of Radiology, Radboud University Nijmegen Medical Centre, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands, W.vandeVen@rad.umcn.nl.
      sug:
        subj:
          Algorithms
          Image Interpretation, Computer Assisted Methods
          Magnetic Resonance Imaging Methods
          Models, Biological Methods
          Prostatic Neoplasms
          Subtraction Technique
          Computer Simulation
          Human
          Image Enhancement Methods
          Male
          Prognosis
          Reproducibility of Results
          Sensitivity and Specificity
          Male
      ab: Objectives: To estimate the required spatial alignment accuracy for correctly grading 95 % of peripheral zone (PZ) prostate cancers using a system for multiparametric magnetic resonance (MR)-guided ultrasound (US) biopsies.Methods: PZ prostate tumours were retrospectively annotated on multiparametric MR series using prostatectomy specimens as reference standard. Tumours were grouped based on homogeneous and heterogeneous apparent diffusion coefficient (ADC) values using an automated ADC texture analysis method. The proportion of heterogeneous tumours containing a distinct, high Gleason grade tumour focus yielding low ADC values was determined. Both overall tumour and high-grade focal volumes were calculated. All high-grade target volumes were then used in a simulated US biopsy system with adjustable accuracy to determine the hit rate.Results: An ADC-determined high-grade tumour focus was found in 63 % of the PZ prostate tumours. The focal volumes were significantly smaller than the total tumour volumes (median volume of 0.3 ml and 1.1 ml respectively). To correctly grade 95 % of the aggressive tumour components the target registration error (TRE) should be smaller than 1.9 mm.Conclusions: To enable finding the high Gleason grade component in 95 % of PZ prostate tumours with MR-guided US biopsies, a technical registration accuracy of 1.9 mm is required.Key Points: • MRI can identify foci of prostatic cancer with reduced apparent diffusion coefficients • Sixty-three per cent of prostatic peripheral zone tumours contain high-grade tumour low ADC foci • The median volume of such foci is 0.3 ml • Biopsy targets are significantly smaller than whole tumour volumes • Simulated registration accuracy is 1.9 mm for correctly grading 95 % of tumours.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N