Efficacy of phototherapy devices and outcomes among extremely low birth weight infants: multi-center observational study.
Objective:Evaluate the efficacy of phototherapy (PT) devices and the outcomes of extremely premature infants treated with those devices.Study Design:This substudy of the National Institute of Child Health and Human Development Neonatal Research Network PT trial included 1404 infants treated with a s...
| Published in: | Journal of Perinatology Vol. 33; no. 2; pp. 126 - 134 |
|---|---|
| Main Authors: | , , , , , , , , , , , , , |
| Format: | research tables/charts Journal Article |
| Published: |
Springer Nature
Feb2013
|
| Online Access: | View this record in EBSCOhost |
| fields | @attributes: recordID: 1 pdfLink: plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=104304478&site=ehost-live header: @attributes: shortDbName: ccm uiTerm: 104304478 longDbName: CINAHL Complete uiTag: AN controlInfo: bkinfo: dissinfo: jinfo: jid: 07438346 DZF jtl: Journal of Perinatology issn: 07438346 maglogo: Y pubinfo: dt: Feb2013 vid: 33 iid: 2 pid: 2579 pub: Springer Nature place: Dordrecht, <Blank> artinfo: ui: 104304478 85166325 10.1038/jp.2012.39 NLM22499082 104304478 ppf: 126 ppct: 8 formats: fmt: @attributes: type: P tig: atl: Efficacy of phototherapy devices and outcomes among extremely low birth weight infants: multi-center observational study. aug: au: Morris, B H Tyson, J E Stevenson, D K Oh, W Phelps, D L O'Shea, T M McDavid, G E Van Meurs, K P Vohr, B R Grisby, C Yao, Q Kandefer, S Wallace, D Higgins, R D affil: Department of Neonatology, Trinity Mother Frances Health System, Tyler, TX, USA sug: subj: Phototherapy Equipment and Supplies Treatment Outcomes Infant, Very Low Birth Weight Human Funding Source Multicenter Studies Nonexperimental Studies Descriptive Statistics Intensive Care Units, Neonatal Relative Risk Poisson Distribution Data Analysis Software Chi Square Test Male Female Male Female ab: Objective:Evaluate the efficacy of phototherapy (PT) devices and the outcomes of extremely premature infants treated with those devices.Study Design:This substudy of the National Institute of Child Health and Human Development Neonatal Research Network PT trial included 1404 infants treated with a single type of PT device during the first 24±12 h of treatment. The absolute (primary outcome) and relative decrease in total serum bilirubin (TSB) and other measures were evaluated. For infants treated with one PT type during the 2-week intervention period (n=1223), adjusted outcomes at discharge and 18 to 22 months corrected age were determined.Result:In the first 24 h, the adjusted absolute (mean (±s.d.)) and relative (%) decrease in TSB (mg dl−1) were: light-emitting diodes (LEDs) −2.2 (±3), −22%; Spotlights −1.7 (±2), −19%; Banks −1.3 (±3), −8%; Blankets −0.8 (±3), −1%; (P<0.0002). Some findings at 18 to 22 months differed between groups.Conclusion:LEDs achieved the greatest initial absolute reduction in TSB but were similar to Spots in the other performance measures. Long-term effects of PT devices in extremely premature infants deserve rigorous evaluation. pubtype: Academic Journal doctype: research tables/charts Journal Article ougenre: Article language: English refInfo: holdings: @attributes: islocal: N |
|---|