The use of individual cut points from treadmill walking to assess free-living moderate to vigorous physical activity in obese subjects by accelerometry: is it useful?

Background: Variation in counts between subjects at a given speed or work rate are the most important source of error in physical activity (PA) measurements with accelerometers. The aim of this study was to explore how the use of individual accelerometer cut points (ICPs) affected the analysis of PA...

Descripción completa

Detalles Bibliográficos
Publicado en:BMC Medical Research Methodology Vol. 12; no. 1; pp. 172 - 173
Autores principales: Aadland, Eivind, Steene-Johannessen, Jostein
Formato: research Journal Article
Publicado: BioMed Central 2012
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=104307009&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 104307009
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        14712288
        1CI1
      jtl: BMC Medical Research Methodology
      issn: 14712288
      maglogo: N
    pubinfo:
      dt: 2012
      vid: 12
      iid: 1
      pid: 24147
      pub: BioMed Central
    artinfo:
      ui:
        104307009
        NLM23152980
        2011923029
        10.1186/1471-2288-12-172
        NLM23152980
        PMC3533971
        104307009
      ppf: 172
      ppct: 1
      formats:
      tig:
        atl: The use of individual cut points from treadmill walking to assess free-living moderate to vigorous physical activity in obese subjects by accelerometry: is it useful?
      aug:
        au:
          Aadland, Eivind
          Steene-Johannessen, Jostein
        affil: Sogn og Fjordane University College, Faculty of Health Studies, Box 523, Førde, 6803, Norway. eivind.aadland@hisf.no.
      sug:
        subj:
          Exercise
          Exercise Test
          Obesity
          Walking
          Adult
          Body Mass Index
          Female
          Human
          Male
          Monitoring, Physiologic
          Motor Activity
          Oxygen Consumption
          Behavior
          Adult: 19-44 years
          Female
          Male
      ab: Background: Variation in counts between subjects at a given speed or work rate are the most important source of error in physical activity (PA) measurements with accelerometers. The aim of this study was to explore how the use of individual accelerometer cut points (ICPs) affected the analysis of PA field data.Methods: We performed a treadmill calibration protocol to determine cut points for moderate to vigorous PA (MVPA) (≥3 metabolic equivalents) and assessed free-living PA in 44 severely obese subjects using the Actigraph GT1M accelerometer. We obtained cut points in 42 subjects (11 men, mean (standard deviation) of body mass index (BMI) 39.8 (5.7), age 43.2 (9.2) years), of whom 35 had valid measurement of free-living PA (minutes of MVPA/day). Linear regression was used to analyze associations with the ICPs and time in MVPA/day. MVPA/day was also compared with values derived using a group cut point (GCP).Results: Resting oxygen consumption (partial r = 0.74, p < .001), work economy (partial r = -0.76, p < .001) and BMI (partial r = 0.52, p = .001) explained 68.4% of the variation in the ICPs (F = 26.7, p < .001). The ICPs explained 79.1% of the variation in the minutes spent in MVPA/day. Moderate to vigorous PA/day derived from the ICPs vs. the GCP varied substantially (R2 = 14%, p = .023, coefficient of variation = 45.1%).Conclusions: The results indicate that the use of ICPs had a strong influence on the PA level. Two thirds of the variation in the ICPs could be explained, however, a certain degree of measurement error will be present. Thus, we are not able to conclude with respect to the most appropriate procedure for analyzing time in MVPA.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N