Oxygen-enhanced lung magnetic resonance imaging: influence of inversion pulse slice selectivity on inversion recovery half-Fourier single-shot turbo spin-echo signal.

Purpose: The purpose of this study was to evaluate in vivo the influence of inversion pulse slice selectivity on oxygen-enhanced magnetic resonance imaging (MRI).Materials and Methods: Thirteen healthy volunteers were studied with a two-dimensional cardiac- and respiratory-gated adiabatic inversion-...

Descripción completa

Detalles Bibliográficos
Publicado en:Japanese Journal of Radiology Vol. 29; no. 4; pp. 244 - 251
Autores principales: Takenaka D, Puderbach M, Ohno Y, Risse F, Ley S, Sugimura K, Kauczor HU, Takenaka, Daisuke, Puderbach, Michael, Ohno, Yoshiharu, Risse, Frank, Ley, Sebastian, Sugimura, Kazuro, Kauczor, Hans-Ulrich
Formato: research Journal Article
Publicado: Springer Nature May2011
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=104710575&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 104710575
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        18671071
        AUCM
      jtl: Japanese Journal of Radiology
      issn: 18671071
      maglogo: N
    pubinfo:
      dt: May2011
      vid: 29
      iid: 4
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        104710575
        60766961
        NLM21607837
        2011067751
        10.1007/s11604-010-0548-4
        NLM21607837
        104710575
      ppf: 244
      ppct: 7
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: Oxygen-enhanced lung magnetic resonance imaging: influence of inversion pulse slice selectivity on inversion recovery half-Fourier single-shot turbo spin-echo signal.
      aug:
        au:
          Takenaka D
          Puderbach M
          Ohno Y
          Risse F
          Ley S
          Sugimura K
          Kauczor HU
          Takenaka, Daisuke
          Puderbach, Michael
          Ohno, Yoshiharu
          Risse, Frank
          Ley, Sebastian
          Sugimura, Kazuro
          Kauczor, Hans-Ulrich
        affil: Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe 650-0017, Japan
      sug:
        subj:
          Lung Anatomy and Histology
          Magnetic Resonance Imaging Methods
          Oxygen Metabolism
          Adult
          Electrocardiography
          Female
          Mathematics
          Image Processing, Computer Assisted
          Male
          Models, Statistical
          Phantoms, Imaging
          Reproducibility of Results
          Adult: 19-44 years
          Female
          Male
      ab: Purpose: The purpose of this study was to evaluate in vivo the influence of inversion pulse slice selectivity on oxygen-enhanced magnetic resonance imaging (MRI).Materials and Methods: Thirteen healthy volunteers were studied with a two-dimensional cardiac- and respiratory-gated adiabatic inversion-recovery half-Fourier single-shot turbo spin-echo (HASTE) sequence with either slice-selective or non-slice-selective inversion recovery (IR) pulse at inversion times increasing from 300 to 1400 ms. The signal-to-noise ratio (SNR) at every inversion time (TI), real signal difference (ΔSI), and relative enhancement ratio of lung parenchyma at TI ≥ 800 ms were statistically compared for oxygen-enhanced and non-oxygen-enhanced MR images with slice-selective or non-slice-selective IR pulses.Results: The SNRs of acquisitions with slice-selective IR pulses were significantly higher than those of non-slice-selective IR pulses (P < 0.05). At TI 800 ms, the ΔSI of lung parenchyma on IR-HASTE images with slice-selective inversion pulse type was significantly higher than on that with the non-slice-selective type (P < 0.05). Relative enhancement ratios of the slice-selective IR pulses were significantly lower than those of non-slice-selective IR pulses at TIs between 800 and 1400 ms (P < 0.05).Conclusion: Slice selectivity of inversion pulse type affects oxygen-enhanced MRI in vivo.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N