Commercial software upgrades may significantly alter Perfusion CT parameter values in colorectal cancer.

Objective: To determine how commercial software platform upgrades impact on derived parameters for colorectal cancer.Materials and Methods: Following ethical approval, 30 patients with suspected colorectal cancer underwent Perfusion CT using integrated 64 detector PET/CT before surgery. Analysis was...

Descripción completa

Detalles Bibliográficos
Publicado en:European Radiology Vol. 21; no. 4; pp. 744 - 750
Autores principales: Goh V, Shastry M, Engledow A, Reston J, Wellsted DM, Peck J, Endozo R, Rodriguez-Justo M, Taylor SA, Halligan S, Groves AM, Goh, Vicky, Shastry, Manu, Engledow, Alec, Reston, Jonathan, Wellsted, David M, Peck, Jacqui, Endozo, Raymondo, Rodriguez-Justo, Manuel, Taylor, Stuart A
Formato: research Journal Article
Publicado: Springer Nature Apr2011
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=104835388&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 104835388
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        09387994
        NPH
      jtl: European Radiology
      issn: 09387994
      maglogo: N
    pubinfo:
      dt: Apr2011
      vid: 21
      iid: 4
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        104835388
        58721749
        NLM20922392
        2010967838
        10.1007/s00330-010-1967-4
        NLM20922392
        104835388
      ppf: 744
      ppct: 6
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: Commercial software upgrades may significantly alter Perfusion CT parameter values in colorectal cancer.
      aug:
        au:
          Goh V
          Shastry M
          Engledow A
          Reston J
          Wellsted DM
          Peck J
          Endozo R
          Rodriguez-Justo M
          Taylor SA
          Halligan S
          Groves AM
          Goh, Vicky
          Shastry, Manu
          Engledow, Alec
          Reston, Jonathan
          Wellsted, David M
          Peck, Jacqui
          Endozo, Raymondo
          Rodriguez-Justo, Manuel
          Taylor, Stuart A
        affil: Paul Strickland Scanner Centre, Mount Vernon Hospital, Rickmansworth Road, Northwood, Middlesex HA6 2RN, UK
      sug:
        subj:
          Adenocarcinoma Radiography
          Colonic Neoplasms Radiography
          Colorectal Neoplasms Radiography
          Radiographic Image Interpretation, Computer-Assisted Equipment and Supplies
          Rectal Neoplasms Radiography
          Tomography, X-Ray Computed Methods
          Adenocarcinoma Surgery
          Aged
          Aged, 80 and Over
          Colonic Neoplasms Surgery
          Colorectal Neoplasms Surgery
          Contrast Media Pharmacodynamics
          Female
          Human
          Male
          Middle Age
          Perfusion
          Radiographic Image Interpretation, Computer-Assisted Methods
          Rectal Neoplasms Surgery
          Software
          Aged: 65+ years
          Aged, 80 & over
          Middle Aged: 45-64 years
          Female
          Male
      ab: Objective: To determine how commercial software platform upgrades impact on derived parameters for colorectal cancer.Materials and Methods: Following ethical approval, 30 patients with suspected colorectal cancer underwent Perfusion CT using integrated 64 detector PET/CT before surgery. Analysis was performed using software based on modified distributed parameter analysis (Perfusion software version 4; Perfusion 4.0), then repeated using the previous version (Perfusion software version 3; Perfusion 3.0). Tumour blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface area product (PS) were determined for identical regions-of-interest. Slice-by-slice and 'whole tumour' variance was assessed by Bland-Altman analysis.Results: Mean BF, BV and PS was 20.4%, 59.5%, and 106% higher, and MTT 14.3% shorter for Perfusion 4.0 than Perfusion 3.0. The mean difference (95% limits of agreement) were +13.5 (-44.9 to 72.0), +2.61 (-0.06 to 5.28), -1.23 (-6.83 to 4.36), and +14.2 (-4.43 to 32.8) for BF, BV, MTT and PS respectively. Within subject coefficient of variation was 36.6%, 38.0%, 27.4% and 60.6% for BF, BV, MTT and PS respectively indicating moderate to poor agreement.Conclusion: Software version upgrades of the same software platform may result in significantly different parameter values, requiring adjustments for cross-version comparison.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N