Verification of In Situ Thresholds and Integrated Real-Ear Measurements.

Background: Accurate prescriptive gain results in a more accurate fit, lower return rate in hearing aids, and increased patient satisfaction. In situ threshold measurements can be used to determine required gain. The Widex Corporation uses an in situ threshold measurement strategy, called the Sensog...

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of the American Academy of Audiology Vol. 21; no. 10; pp. 663 - 671
Autores principales: DiGiovanni, Jeffrey J., Pratt, Ryan M.
Formato: research tables/charts Journal Article
Publicado: Thieme Medical Publishing Inc. Nov2010
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=104850690&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 104850690
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        10500545
        9OC
      jtl: Journal of the American Academy of Audiology
      issn: 10500545
      maglogo: Y
    pubinfo:
      dt: Nov2010
      vid: 21
      iid: 10
      pid: 2811
      pub: Thieme Medical Publishing Inc.
      place: New York, New York
    artinfo:
      ui:
        104850690
        59495219
        10.3766/jaaa.21.10.6
        NLM21376007
        104850690
      ppf: 663
      ppct: 8
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Verification of In Situ Thresholds and Integrated Real-Ear Measurements.
      aug:
        au:
          DiGiovanni, Jeffrey J.
          Pratt, Ryan M.
        affil: Communication Sciences and Disorders, Ohio University
      sug:
        subj:
          Hearing Aids
          Assistive Listening Systems
          Hearing Loss, Sensorineural Diagnosis
          Human
          Repeated Measures
          Analysis of Variance
          Fisher's Exact Test
          Post Hoc Analysis
      ab: Background: Accurate prescriptive gain results in a more accurate fit, lower return rate in hearing aids, and increased patient satisfaction. In situ threshold measurements can be used to determine required gain. The Widex Corporation uses an in situ threshold measurement strategy, called the Sensogram. Real-ear measurements determine if prescriptive gain targets have been achieved. Starkey Laboratories introduced an integrated real-ear measurement system in their hearing aids. Purpose: To determine whether the responses obtained using the Widex Sensogram were equivalent to those obtained using current clinical threshold measurement methods. To determine the accuracy of the Starkey IREMS™ (Integrated Real Ear Measurement System) in measuring RECD (real-ear to coupler difference) values compared to a dedicated real-ear measurement system. Research Design: A verification design was employed by comparing participant data measured from standard, benchmark equipment and procedures against new techniques offered by hearing-aid manufacturers. Study Sample: A total of 20 participants participated in this study. Ten participants with sensorineural hearing loss were recruited from the Ohio University Hearing, Speech, and Language Clinic participated in the first experiment. Ten participants with normal hearing were recruited from the student population at Ohio University participated in both experiments. The normal-hearing group had thresholds of 15 dB HL or better at the octave frequencies of 250-8000 Hz. The hearing-impaired group had thresholds of varying degrees and configurations with thresholds equal to or poorer than 25 dB HL three-frequency puretone average. Data Collection and Analysis: The order of measurement method for both experiments was counterbalanced. In Experiment 1, thresholds obtained via the Widex Sensogram were compared to thresholds obtained for each participant using a clinical audiometer and ER-3A insert ear phones. In Experiment 2, RECD values obtained via the Starkey IREMS were compared to RECD values obtained via the Audioscan Verifit™. A repeated-measures analysis of variance (ANOVA) was used for statistical analysis, and a Fisher's LSD (least significant difference) was used as a post hoc analysis tool. Results: A significant difference between Sensogram thresholds and conventional audiometric thresholds was found with the Sensogram method resulting in better threshold values at 0.5, 1.0, and 2.0 kHz for both groups. In Experiment 2, a significant difference between RECD values obtained by the Starkey IREMS and the Audioscan Verifit system was found with significant differences in RECD values found at 0.25, 0.5, 0.75, 1.5, 2.0, and 6.0 kHz. Conclusions: The Sensogram data differ significantly from traditional audiometry at several frequencies important for speech intelligibility. Real-ear measures are still required for verification of prescribed gain, however, calling into question any claims of shortened fitting time. The Starkey IREMS does perform real-ear measurements that vary significantly from benchmark equipment. These technologies represent a positive direction in prescribing accurate gain during hearing-aid fittings, but a stand-alone system is still the preferred method for real-ear measurements in hearing-aid fittings.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N