Superior fixation of pegged trabecular metal over screw-fixed pegged porous titanium fiber mesh.

Background and purpose Lasting stability of cementless implants depends on osseointegration into the implant surface, and long-term implant fixation can be predicted using radiostereometric analysis (RSA) with short-term follow-up. We hypothesized that there would be improved fixation of high-porosi...

Descripción completa

Detalles Bibliográficos
Publicado en:Acta Orthopaedica Vol. 82; no. 2; pp. 177 - 187
Autores principales: Stilling, Maiken, Madsen, Frank, Odgaard, Anders, Røømer, Lone, Andersen, Niels Trolle, Rahbek, Ole, Søøballe, Kjeld
Formato: clinical trial equations & formulas pictorial research tables/charts Journal Article
Publicado: Medical Journals Sweden AB Apr2011
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=104862821&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 104862821
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        17453674
        1BVL
      jtl: Acta Orthopaedica
      issn: 17453674
      maglogo: N
    pubinfo:
      dt: Apr2011
      vid: 82
      iid: 2
      pid: 59195
      pub: Medical Journals Sweden AB
    artinfo:
      ui:
        104862821
        59761498
        10.3109/17453674.2011.566139
        NLM21434781
        104862821
      ppf: 177
      ppct: 10
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Superior fixation of pegged trabecular metal over screw-fixed pegged porous titanium fiber mesh.
      aug:
        au:
          Stilling, Maiken
          Madsen, Frank
          Odgaard, Anders
          Røømer, Lone
          Andersen, Niels Trolle
          Rahbek, Ole
          Søøballe, Kjeld
        affil: Department of Orthopedics
      sug:
        subj:
          Osteoarthritis Surgery
          Orthopedic Prosthesis Evaluation
          Orthopedic Fixation Devices Evaluation
          Arthroplasty, Replacement, Knee Equipment and Supplies
          Foreign-Body Migration
          Human
          Clinical Trials
          Random Assignment
          Prospective Studies
          Radiostereometric Analysis
          Titanium
          Metals
          Pretest-Posttest Design
          Descriptive Statistics
          T-Tests
          Prosthesis Design
          Funding Source
          Academic Medical Centers
          Denmark
          Adolescence
          Adult
          Middle Age
          Aged
          Male
          Female
          Scales
          Treatment Outcomes
          Patient Satisfaction
          Mann-Whitney U Test
          Wilcoxon Signed Rank Test
          Data Analysis Software
          Chi Square Test
          Fisher's Exact Test
          Paired T-Tests
          Adolescent: 13-18 years
          Adult: 19-44 years
          Middle Aged: 45-64 years
          Aged: 65+ years
          Male
          Female
      ab: Background and purpose Lasting stability of cementless implants depends on osseointegration into the implant surface, and long-term implant fixation can be predicted using radiostereometric analysis (RSA) with short-term follow-up. We hypothesized that there would be improved fixation of high-porosity trabecular metal (TM) tibial components compared to low-porosity titanium pegged porous fiber-metal (Ti) polyethylene metal backings. Methods In a prospective, parallel-group, randomized unblinded clinical trial, we compared cementless tibial components in patients aged 70 years and younger with osteoarthritis. The pre-study sample size calculation was 22 patients per group. 25 TM tibial components were fixed press-fit by 2 hexagonal pegs (TM group) and 25 Ti tibial components were fixed press-fit and by 4 supplemental screws (Ti group). Stereo radiographs for evaluation of absolute component migration (primary effect size) and single-direction absolute component migration (secondary effect size) were obtained within the first postoperative week and at 6 weeks, 6 months, 1 year, and 2 years. American Knee Society score was used for clinical assessment preoperatively, and at 1 and 2 years. Results There were no intraoperative complications, and no postoperative infections or revisions. All patients had improved function and regained full extension. All tibial components migrated initially. Most migration of the TM components (n == 24) occurred within the first 3 months after surgery whereas migration of the Ti components (n == 22) appeared to stabilize first after 1 year. The TM components migrated less than the Ti components at 1 year (p == 0.01) and 2 years (p == 0.004). Interpretation We conclude that the mechanical fixation of TM tibial components is superior to that of screw-fixed Ti tibial components. We expect long-term implant survival to be better with the TM tibial component.
      pubtype: Academic Journal
      doctype:
        clinical trial
        equations & formulas
        pictorial
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N