Comparison of Two Different Speckle Tracking Software Systems: Does the Method Matter?

Background: Echocardiographic speckle tracking strain has gained clinical importance. However, the comparability of measurements between different software systems is not well defined. Methods: In 47 healthy subjects left ventricular (LV) two-dimensional (2D) peak strain and time to peak strain (TTP...

Descripción completa

Detalles Bibliográficos
Publicado en:Echocardiography Vol. 28; no. 5; pp. 539 - 548
Autores principales: Biaggi, Patric, Carasso, Shemy, Garceau, Patrick, Greutmann, Matthias, Gruner, Christiane, Tsang, Wendy, Rakowski, Harry, Agmon, Yoram, Woo, Anna
Formato: diagnostic images pictorial research tables/charts Journal Article
Publicado: Wiley-Blackwell May2011
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=104897114&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 104897114
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        07422822
        GSE
      jtl: Echocardiography
      issn: 07422822
      maglogo: Y
    pubinfo:
      dt: May2011
      vid: 28
      iid: 5
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        104897114
        60572975
        10.1111/j.1540-8175.2011.01386.x
        NLM21517954
        104897114
      ppf: 539
      ppct: 9
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Comparison of Two Different Speckle Tracking Software Systems: Does the Method Matter?
      aug:
        au:
          Biaggi, Patric
          Carasso, Shemy
          Garceau, Patrick
          Greutmann, Matthias
          Gruner, Christiane
          Tsang, Wendy
          Rakowski, Harry
          Agmon, Yoram
          Woo, Anna
        affil: Division of Cardiology, Peter Munk Cardiac Program, Toronto General Hospital, University Health Network, Toronto, Ontario, Canada
      sug:
        subj:
          Echocardiography Methods
          Software
          Image Interpretation, Computer Assisted
          Heart Ventricle, Left Ultrasonography
          Comparative Studies
          Pearson's Correlation Coefficient
          Human
          Canada
          Israel
          Intrarater Reliability
          Interrater Reliability
          Descriptive Statistics
          Paired T-Tests
          One-Way Analysis of Variance
          Post Hoc Analysis
          Data Analysis Software
          Male
          Female
          Adult
          Middle Age
          Reproducibility of Results
          Adult: 19-44 years
          Middle Aged: 45-64 years
          Male
          Female
      ab: Background: Echocardiographic speckle tracking strain has gained clinical importance. However, the comparability of measurements between different software systems is not well defined. Methods: In 47 healthy subjects left ventricular (LV) two-dimensional (2D) peak strain and time to peak strain (TTP) generated by EchoPAC (2DS) and velocity vector imaging (VVI) were compared. For each type of strain (longitudinal [LS], circumferential [CS], and radial strain [RS]) we compared global, anatomical level and segmental values. Results: When comparing 2DS to VVI, Pearson correlation coefficients (r) of global LS, CS, and RS were 0.68, 0.44, and 0.59, respectively (all P < 0.05). Correlation of global TTP was higher: 0.81(LS), 0.80 (CS), and 0.68 (RS), all P < 0.01. Segmental peak strain differed significantly between 2DS and VVI in 8/18 (LS), 17/18 (CS), and 15/18 (RS) LV segments (P < 0.05). However, segmental TTP significantly differed only in 5/18 (LS), 7/18 (CS), and 4/18 (RS) of LV segments. Similar strain gradients were found for both systems: apical strain was higher than basal and midventricular strain in LS and CS, with a reversed pattern for RS (P < 0.05). Conclusion: TTP strain as well as strain gradients were comparable between VVI and 2DS, but most peak strain values were not. The software-dependency of peak strain values must be considered in clinical application. Further studies comparing the diagnostic and prognostic accuracy of strain values generated by different software systems are mandatory. (Echocardiography 2011;28:539-547)
      pubtype: Academic Journal
      doctype:
        diagnostic images
        pictorial
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N