Image quality in low-dose multidetector computed tomography: a pilot study to assess feasibility and dose optimization in whole-body bone imaging.

Objective: To study the impact of dose parameters on image quality at whole-body low-dose multidetector computed tomography (CT) in an attempt to derive parameters that allow diagnostic quality images of the skeletal system without incurring significant radiation dose in patients referred for invest...

Descripción completa

Detalles Bibliográficos
Publicado en:Canadian Association of Radiologists Journal Vol. 61; no. 5; pp. 258 - 265
Autores principales: Gleeson TG, Byrne B, Kenny P, Last J, Fitzpatrick P, O'Gorman P, Eustace SJ
Formato: diagnostic images equations & formulas pictorial research tables/charts Journal Article
Publicado: Sage Publications Inc. Dec2010
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=104970762&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 104970762
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        08465371
        0CD
      jtl: Canadian Association of Radiologists Journal
      issn: 08465371
      maglogo: Y
    pubinfo:
      dt: Dec2010
      vid: 61
      iid: 5
      pid: 344
      pub: Sage Publications Inc.
      place: Thousand Oaks, California
    artinfo:
      ui:
        104970762
        56518695
        10.1016/j.carj.2010.01.003
        NLM20189749
        104970762
      ppf: 258
      ppct: 7
      formats:
      tig:
        atl: Image quality in low-dose multidetector computed tomography: a pilot study to assess feasibility and dose optimization in whole-body bone imaging.
      aug:
        au:
          Gleeson TG
          Byrne B
          Kenny P
          Last J
          Fitzpatrick P
          O'Gorman P
          Eustace SJ
        affil: Department of Radiology and Diagnostic Imaging, Mater Misericordiae University Hospital, Dublin, Ireland.
      sug:
        subj:
          Tomography Methods
          Paraproteinemias Radiography
          Dosage Calculation
          Human
          Ireland
          Pilot Studies
          kappa Statistic
          Summated Rating Scaling
          Quality Assurance
          Equipment and Supplies
          Confidence Intervals
      ab: Objective: To study the impact of dose parameters on image quality at whole-body low-dose multidetector computed tomography (CT) in an attempt to derive parameters that allow diagnostic quality images of the skeletal system without incurring significant radiation dose in patients referred for investigation of plasma cell dyscrasias. Methods: By using a single cadaver, 14 different whole-body low-dose CT protocols were individually assessed by 2 radiologists, blinded to acquisition parameters (kVp and mAs, reconstruction algorithm, dose reduction software). Combinations of kVps that range from 80-140 kVp, and tube current time product from 14-125 mAs were individually scored by using a Likért scale from 1-5 in 4 separate anatomical areas (skull base, thoracic spine, pelvis, and distal femora). Correlation between readers scores and effective doses were obtained by using correlation coefficient statistical analysis, statistical significance was considered P < .01. Interobserver agreement was assessed by using a Bland and Altman plot. Interobserver agreement in each of the 4 anatomical areas was assessed by using kappa statistics. A single set of parameters was then selected for use in future clinical trials in a cohort of patients referred for investigation of monoclonal gammopathy, including multiple myeloma. Results: Several sets of exposure parameters allowed low-dose whole-body CT to be performed with effective doses similar to skeletal survey while preserving diagnostic image quality. Individual reader's and average combined scores showed a strong inverse correlation with effective dose (reader 1, r = -0.78, P = .0001; reader 2, r = -0.75, P = .0003); average combined scores r = -0.81, P < .0001). Bland and Altman plot of overall scores shows reasonable interobserver agreement, with a mean difference of 1.055. Conclusion: Whole-body low-dose CT can be used to obtain adequate CT image quality to assess normal osseous detail while delivering effective doses similar to those associated with conventional radiographic skeletal survey.