Minimal detectable change of the timed 'up & go' test and the dynamic gait index in people with parkinson disease.

Background. The minimal detectable change (MDC) is the smallest amount of difference in individual scores that represents true change (beyond random measurement error). The MDCs of the Timed "Up & Go" Test (TUG) and the Dynamic Gait Index (DGI) in people with Parkinson disease (PD) are largely unkno...

Descripción completa

Detalles Bibliográficos
Publicado en:Physical Therapy Vol. 91; no. 1; pp. 114 - 122
Autores principales: Huang S, Hsieh C, Wu R, Tai C, Lin C, Lu W
Formato: equations & formulas research tables/charts Journal Article
Publicado: Oxford University Press / USA Jan2011
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=104991124&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 104991124
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        00319023
        PTH
      jtl: Physical Therapy
      issn: 00319023
      maglogo: N
    pubinfo:
      dt: Jan2011
      vid: 91
      iid: 1
      pid: 10398
      pub: Oxford University Press / USA
    artinfo:
      ui:
        104991124
        104991124
        2010913939
        10.2522/ptj.20090126
        NLM20947672
        104991124
      ppf: 114
      ppct: 8
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Minimal detectable change of the timed 'up & go' test and the dynamic gait index in people with parkinson disease.
      aug:
        au:
          Huang S
          Hsieh C
          Wu R
          Tai C
          Lin C
          Lu W
        affil: Lecturer, School of Occupational Therapy, College of Medicine, National Taiwan UniversitySenior Occupational Therapist, Division of Occupational Therapy, Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Taipei, Taiwan
      sug:
        subj:
          Parkinson Disease Physiopathology
          Clinical Assessment Tools Evaluation
          Measurement Issues and Assessments
          Human
          Prospective Studies
          Test-Retest Reliability
          Convenience Sample
          Clinical Assessment Tools
          Scales
          Middle Age
          Aged
          Female
          Male
          Data Analysis Software
          Intraclass Correlation Coefficient
          Repeated Measures
          Two-Way Analysis of Variance
          Confidence Intervals
          Pearson's Correlation Coefficient
          Funding Source
          Middle Aged: 45-64 years
          Aged: 65+ years
          Female
          Male
      ab: Background. The minimal detectable change (MDC) is the smallest amount of difference in individual scores that represents true change (beyond random measurement error). The MDCs of the Timed "Up & Go" Test (TUG) and the Dynamic Gait Index (DGI) in people with Parkinson disease (PD) are largely unknown, limiting the interpretability of the change scores of both measures. Objective. The purpose of this study was to estimate the MDCs of the TUG and the DGI in people with PD. Design. This investigation was a prospective cohort study. Methods. Seventy-two participants were recruited from special clinics for movement disorders at a university hospital. Their mean age was 67.5 years, and 61% were men. All participants completed the TUG and the DGI assessments twice, about 14 days apart. The MDC was calculated from the standard error of measurement. The percentage MDC (MDC%) was calculated as the MDC divided by the mean of all scores for the sample. Furthermore, the intraclass correlation coefficient was used to examine the reproducibility between testing sessions (test-retest reliability). Results. The respective MDC and MDC% of the TUG were 3.5 seconds and 29.8, and those of the DGI were 2.9 points and 13.3. The test-retest reliability values for the TUG and the DGI were high; the intraclass correlation coefficients were .80 and .84, respectively. Limitations. The study sample was a convenience sample, and the participants had mild to moderately severe PD. Conclusions. The results showed that the TUG and the DGI have generally acceptable random measurement error and test-retest reliability. These findings should help clinicians and researchers determine whether a change in an individual patient with PD is a true change.
      pubtype: Academic Journal
      doctype:
        equations & formulas
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N