Characteristics of telemetry interference with pacemakers caused by digital media players.

Background: Contemporary implantable heart rhythm devices communicate multiple complex data simultaneously using radiofrequency telemetry. Interference in communication can expose them to the risk of potential corruption, leading to adverse clinical consequences. Methods & Results: We studied the ch...

Descripción completa

Detalles Bibliográficos
Publicado en:Pacing & Clinical Electrophysiology Vol. 33; no. 6; pp. 712 - 721
Autores principales: Shah AJ, Brunett JD, Thaker JP, Patel MB, Liepa VV, Jongnarangsin K, Thakur RK
Formato: pictorial research tables/charts tracings Journal Article
Publicado: Wiley-Blackwell Jun2010
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=105026534&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 105026534
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        01478389
        4F8
      jtl: Pacing & Clinical Electrophysiology
      issn: 01478389
      maglogo: Y
    pubinfo:
      dt: Jun2010
      vid: 33
      iid: 6
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        105026534
        2010682978
        10.1111/j.1540-8159.2009.02672.x
        NLM20059718
        105026534
      ppf: 712
      ppct: 9
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Characteristics of telemetry interference with pacemakers caused by digital media players.
      aug:
        au:
          Shah AJ
          Brunett JD
          Thaker JP
          Patel MB
          Liepa VV
          Jongnarangsin K
          Thakur RK
        affil: Thoracic and Cardiovascular Institute, Sparrow Health System, Michigan State University, Lansing, Michigan
      sug:
        subj:
          Communications Media
          Digitizers Evaluation
          Pacemaker, Artificial Evaluation
          Telemetry
          Cardiac Patients Evaluation
          Computers, Hand-Held Evaluation
          Consent
          Electrocardiography Methods
          Electromagnetic Fields
          Electrophysiology
          Female
          Human
          Male
          Prospective Studies
          Protocols
          Technology, Medical
          Female
          Male
      ab: Background: Contemporary implantable heart rhythm devices communicate multiple complex data simultaneously using radiofrequency telemetry. Interference in communication can expose them to the risk of potential corruption, leading to adverse clinical consequences. Methods & Results: We studied the characteristics of interference with uplink (real time intracardiac electrograms, marker channel, and stored histograms) and downlink (attempt to program a change in the lower rate limit, the pacing mode, and the ventricular lead configuration) data transmission between the wand and the pacemaker caused by digital media players (iPods-Photo and 3G) in 50 patients. We also measured and characterized worst-case magnetic field emissions (MFE) from the wand (<=0.4 [mu]T), pacemaker (<=0.004 [mu]T), and iPod (<=0.05 [mu]T) during telemetry to understand the modulation techniques and safety protocols employed during data transmission. Telemetry interference (TI) manifested as high-frequency spikes (24.4%), blanking (17.7%) and interruption (22.2%), or delay (17.6%) in transmission with warning on programmer's screen. TI occurred in 25.6% of patients when the iPod was 'on' and in 13% even with the iPod turned 'off.' There were no inaccuracies in downlinked data when the downlink communication was successful. Wanded telemetry utilizes low-frequency (30-300 kHz) radiowaves and simple digital modulation techniques at relatively slow rates for 'sequential' data transmission protected by a continuous 'handshake.' Emissions from iPods in that range interrupt the telemetry link but are too weak to cause pacemaker malfunction through corruption of vital data. Conclusion: Low-power MFE from iPods can produce interference with establishment and maintenance of a telemetry link and can cause TI with transmission of real time data, but because of continuous check protocols, do not corrupt the stored and vital downlink data. (PACE 2010; 33:712-720)
      pubtype: Academic Journal
      doctype:
        pictorial
        research
        tables/charts
        tracings
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N