Feasibility of dose painting using volumetric modulated arc optimization and delivery.

Purpose. Dose painting strategies are limited by optimization algorithms in treatment planning systems and physical constraints of the beam delivery. We investigate dose conformity using the RapidArc optimizer and beam delivery technique. Furthermore, robustness of the plans with respect to position...

Descripción completa

Detalles Bibliográficos
Publicado en:Acta Oncologica Vol. 49; no. 7; pp. 964 - 972
Autores principales: Korreman SS, Ulrich S, Bowen S, Deveau M, Bentzen SM, Jeraj R
Formato: diagnostic images research tables/charts Journal Article
Publicado: Medical Journals Sweden AB Oct2010
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=105098264&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 105098264
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        0284186X
        B84
      jtl: Acta Oncologica
      issn: 0284186X
      maglogo: N
    pubinfo:
      dt: Oct2010
      vid: 49
      iid: 7
      pid: 59195
      pub: Medical Journals Sweden AB
    artinfo:
      ui:
        105098264
        53508547
        10.3109/0284186X.2010.498440
        105098264
      ppf: 964
      ppct: 8
      formats:
      tig:
        atl: Feasibility of dose painting using volumetric modulated arc optimization and delivery.
      aug:
        au:
          Korreman SS
          Ulrich S
          Bowen S
          Deveau M
          Bentzen SM
          Jeraj R
        affil: University of Wisconsin School of Medicine and Public Health, Department of Human Oncology, Clinical Sciences Center, Madison, Wisconsin, USA
      sug:
        subj:
          Head and Neck Neoplasms Radiotherapy
          Radiation Dosage
          Radiotherapy Methods
          Neck Radiation Effects
          Head Radiation Effects
          Dose-Response Relationship, Radiation
          Radiotherapy, Computer-Assisted
          Funding Source
          Human
      ab: Purpose. Dose painting strategies are limited by optimization algorithms in treatment planning systems and physical constraints of the beam delivery. We investigate dose conformity using the RapidArc optimizer and beam delivery technique. Furthermore, robustness of the plans with respect to positioning uncertainties are evaluated. Methods. A head & neck cancer patient underwent a [61Cu]Cu-ATSM PET/CT-scan. PET-SUVs were converted to prescribed dose with a base dose of 60 Gy, and target mean dose 90 Gy. The voxel-based prescription was converted into 3, 5, 7, 9, and 11 discrete prescription levels. Optimization was performed in Eclipse, varying the following parameters: MLC leaf width (5 mm and 2.5 mm), number of arcs (1 and 2) and collimator rotation (0, 15, 30 and 45 degrees). Dose conformity was evaluated using quality volume histograms (QVHs), and relative volumes receiving within ±5% of prescribed dose (Q0.95–1.05). Deliverability was tested using a Delta4® phantom. Robustness was tested by shifting the isocenter 1 mm and 2 mm in all directions, and recalculating the dose. Results. Good conformity was obtained using MLC leaf width 2.5 mm, two arcs, and collimators 45/315 degrees, with Q0.95–1.05=92.8%, 91.6%, 89.7% and 84.6%. Using only one arc or increasing the MLC leaf width had a small deteriorating effect of 2–5%. Small changes in collimator angle gave small changes, but large changes in collimator angle gave a larger decrease in plan conformity; for angles of 15 and 0 degrees (two arcs, 2.5 mm leaf width), Q0.95–1.05 decreased by up to 15%. Consistency between planned and delivered dose was good, with ∼90% of gamma values <1. For 1 mm shift, Q0.95–1.05 was decreased by 5–15%, while for 2 mm shift, Q0.95–1.05 was decreased to 55–60%. Conclusions. Results demonstrate feasibility of planning of prescription doses with multiple levels for dose painting using RapidArc, and plans were deliverable. Robustness to positional error was low.