Reproducibility and validity of digital inclinometry for measuring cervical range of motion in normal subjects.

Background and Purpose. Measurements of cervical range of motion (CROM) have been extensively reported in the past decade employing simple (goniometers) as well as sophisticated (electro-, magneto- and ultrasonography-based) systems. The recent introduction of the simple, user-friendly and relativel...

Descripción completa

Detalles Bibliográficos
Publicado en:Physiotherapy Research International Vol. 15; no. 1; pp. 42 - 49
Autores principales: Prushansky T, Deryi O, Jabarreen B
Formato: research tables/charts Journal Article
Publicado: Wiley-Blackwell Mar2010
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=105139377&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 105139377
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        13582267
        GPG
      jtl: Physiotherapy Research International
      issn: 13582267
      maglogo: Y
    pubinfo:
      dt: Mar2010
      vid: 15
      iid: 1
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        105139377
        2010587522
        10.1002/pri.443
        NLM19554615
        105139377
      ppf: 42
      ppct: 7
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Reproducibility and validity of digital inclinometry for measuring cervical range of motion in normal subjects.
      aug:
        au:
          Prushansky T
          Deryi O
          Jabarreen B
        affil: Department of Physical Therapy, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv Israel
      sug:
        subj:
          Biophysical Instruments
          Cervical Vertebrae Physiology
          Equipment Reliability
          Neck Physiology
          Range of Motion Evaluation
          Adult
          Analysis of Variance
          Body Weights and Measures
          Comparative Studies
          Confidence Intervals
          Data Analysis Software
          Descriptive Statistics
          Evaluation Research
          Extension Evaluation
          Female
          Flexion Evaluation
          Human
          Intraclass Correlation Coefficient
          Intrarater Reliability
          Male
          Neck Ultrasonography
          Reliability and Validity
          Repeated Measures
          Reproducibility of Results
          Rotation Evaluation
          Sex Factors
          Sitting
          Supine Position
          Test-Retest Reliability
          Young Adult
          Adult: 19-44 years
          Female
          Male
      ab: Background and Purpose. Measurements of cervical range of motion (CROM) have been extensively reported in the past decade employing simple (goniometers) as well as sophisticated (electro-, magneto- and ultrasonography-based) systems. The recent introduction of the simple, user-friendly and relatively cheap digital inclinometer (DI) has opened a potentially new venue for measurement of this segment's motion. The purpose of the present study was to assess intra-tester reproducibility of DI-based findings as well as its validity in comparison to the ultrasonography-based Zebris CMS 70P (Zebris Medizintechnik Gmbh[TM], Isny, Germany) for measuring CROM in normal subjects. Methods. Active CROM of healthy women (n = 15) and men (n = 15) aged 24.2(2.4) years was measured on two sessions, Test 1 and Test 2, spread over 7.2(±0.7) days apart. On Test 1, the six primary movements of the neck (flexion, F; extension, E; right and left lateral flexion, RLF and LLF; and right and left rotations, RR and LR) were measured using the DI and the Zebris. On Test 2, the same measurements were performed using the DI only. All measurements were conducted by the same tester, with the subject in the seated position. The only exception was DI measurement of cervical rotation that was performed in the supine position due to the DI gravity-dependence, rendering DI measurements in the transverse plane irrelevant. Results. No significant differences were revealed between the two instruments with respect to the sagittal and frontal planes, whereas the DI-based CROM in rotation was significantly greater then its Zebris-based counterpart. The inter-device interclass correlation coefficients (ICCs) for the frontal were 0.72 (RLF) and 0.62 (LLF), and 0.77 (F) and 0.83 (E). Poor correlations were indicated for the rotations. The intra-tester reproducibility derived from the test-retest DI measurement indicated good to excellent reproducibility in all planes with ICCs ranging from 0.82 (LLF) to 0.94 (E). The Standard Error of Measurement ranged from 1.6° (RR) to 2.6° (F). Conclusion. DI-based CROM measurements are reproducible and valid for recording sagittal and frontal plane motions in healthy subjects. The higher range in rotations, relative to the Zebris-based findings, is most probably attributable to the test position. Being relatively cheap, portable and convenient for tester and subject alike, the DI seems to be an effective instrument for assessing CROM. Copyright © 2009 John Wiley & Sons, Ltd.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N