Improvement of the air quality in student health centers with chlorine dioxide.
This study aims to monitor bioaerosol levels of a local campus of a student health center in Taiwan and then to perform disinfection by applying chlorine dioxide. First, air samples were taken and evaluated in the six areas of the center. The average background bioaerosol levels were 714 ± 1706 CFU/...
| Published in: | International Journal of Environmental Health Research Vol. 20; no. 2; pp. 115 - 128 |
|---|---|
| Main Authors: | , , |
| Format: | research tables/charts Journal Article |
| Published: |
Taylor & Francis Ltd
Apr2010
|
| Online Access: | View this record in EBSCOhost |
| fields | @attributes: recordID: 1 pdfLink: plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=105139686&site=ehost-live header: @attributes: shortDbName: ccm uiTerm: 105139686 longDbName: CINAHL Complete uiTag: AN controlInfo: bkinfo: dissinfo: jinfo: jid: 09603123 57L jtl: International Journal of Environmental Health Research issn: 09603123 maglogo: Y pubinfo: dt: Apr2010 vid: 20 iid: 2 pid: 377 pub: Taylor & Francis Ltd place: Philadelphia, Pennsylvania artinfo: ui: 105139686 2010587839 10.1080/09603120903440673 NLM20169486 105139686 ppf: 115 ppct: 13 formats: fmt: @attributes: type: P tig: atl: Improvement of the air quality in student health centers with chlorine dioxide. aug: au: Hsu C Huang D Lu M affil: Department of Environmental Resource Management, Chia-Nan University of Pharmacy and Science, Tainan, Taiwan sug: subj: Air Pollution, Indoor Prevention and Control Chlorine Therapeutic Use Sterilization and Disinfection Evaluation Student Health Services Evaluation Data Analysis Software Data Analysis, Statistical Descriptive Statistics Funding Source Multiple Regression One-Way Analysis of Variance P-Value Pearson's Correlation Coefficient Taiwan ab: This study aims to monitor bioaerosol levels of a local campus of a student health center in Taiwan and then to perform disinfection by applying chlorine dioxide. First, air samples were taken and evaluated in the six areas of the center. The average background bioaerosol levels were 714 ± 1706 CFU/m3 for bacterium and 802 ± 633 CFU/m3 for fungi. Then, chlorine dioxide was applied through three different procedures: single, multiple and regular disinfections. The results indicated that both multiple and regular disinfections can achieve efficiency levels higher than 59.0%. The regression analysis on bioaerosol levels showed that the number of people present correlating to the number of persons entering the room per door-opening, had a correlation of p < 0.05. Utilizing this analysis result, an empirical model was developed to predict indoor bioaerosol concentrations. It can be inferred that for indoor human activity of health centers, regular disinfection is a very effective process. pubtype: Academic Journal doctype: research tables/charts Journal Article ougenre: Article language: English refInfo: holdings: @attributes: islocal: N |
|---|