Method for guiding the ablation catheter to the ablation site: a simulation and experimental study.

Radiofrequency catheter ablation (RCA) procedures for treating ventricular arrhythmias have evolved significantly over the past several years; however, the use of RCA has been limited due to the difficulty in identifying the appropriate site for ablation. In this study, we investigate the accuracy o...

Descripción completa

Detalles Bibliográficos
Publicado en:Medical & Biological Engineering & Computing Vol. 47; no. 3; pp. 267 - 279
Autores principales: Fukuoka Y, Oostendorp TF, Armoundas AA, Fukuoka, Yutaka, Oostendorp, Thom F, Armoundas, Antonis A
Formato: research Journal Article
Publicado: Springer Nature Mar2009
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=105219817&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 105219817
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        01400118
        PO0
      jtl: Medical & Biological Engineering & Computing
      issn: 01400118
      maglogo: N
    pubinfo:
      dt: Mar2009
      vid: 47
      iid: 3
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        105219817
        NLM19194733
        2010207064
        10.1007/s11517-009-0441-4
        NLM19194733
        105219817
      ppf: 267
      ppct: 12
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Method for guiding the ablation catheter to the ablation site: a simulation and experimental study.
      aug:
        au:
          Fukuoka Y
          Oostendorp TF
          Armoundas AA
          Fukuoka, Yutaka
          Oostendorp, Thom F
          Armoundas, Antonis A
        affil: School of Biomedical Science, Tokyo Medical and Dental University, Tokyo, Japan
      sug:
        subj:
          Body Surface Potential Mapping Methods
          Catheter Ablation Methods
          Tachycardia, Ventricular Surgery
          Algorithms
          Computer Simulation
          Human
          Models, Biological
          Signal Processing, Computer Assisted
      ab: Radiofrequency catheter ablation (RCA) procedures for treating ventricular arrhythmias have evolved significantly over the past several years; however, the use of RCA has been limited due to the difficulty in identifying the appropriate site for ablation. In this study, we investigate the accuracy of a computer algorithm to guide the tip of an ablation catheter to the exit site of the scar tissue or the site of abnormal automaticity (the "target site"). This algorithm involves modeling the body surface potentials corresponding to the wavefront at the target site for ablation and current pulses generated from a pair of electrodes at the tip of the ablation catheter with a single equivalent moving dipole (SEMD) in an infinite homogeneous volume conductor. Despite the fact that the use of the homogeneous volume conductor introduces systematic error in the estimated compared to the true dipole location, we find that the systematic error had minor influence in the ability of the algorithm to accurately guide the tip of the ablation catheter to the ablation site and the overall error (1.9 +/- 1.1 mm) in the left ventricle is adequate for RCA procedures. These results were verified, in saline tank studies in which the distance between the dipole due to the catheter tip and the dipole due to the target site was found to be 2.66 +/- 0.52 mm. In conclusion, our algorithm to estimate the SEMD parameters from body surface potentials can potentially be a useful method to rapidly and accurately guide the catheter tip to the arrhythmic site during an RCA procedure.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N