Dose reduction by automatic exposure control in multidetector computed tomography: comparison between measurement and calculation.

The aim of this study was to investigate the potential of dose reduction in multidetector computed tomography (MDCT) by current-modulated automatic exposure control (AEC) and to test the reliability of the dose estimation by the conventional CT dosimetry program CT-EXPO, when an average tube current...

Descripción completa

Detalles Bibliográficos
Publicado en:European Radiology Vol. 19; no. 4; pp. 1027 - 1035
Autores principales: Lechel U, Becker C, Langenfeld-Jäger G, Brix G, Lechel, U, Becker, C, Langenfeld-Jäger, G, Brix, G
Formato: research Journal Article
Publicado: Springer Nature Apr2009
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=105220005&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 105220005
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        09387994
        NPH
      jtl: European Radiology
      issn: 09387994
      maglogo: N
    pubinfo:
      dt: Apr2009
      vid: 19
      iid: 4
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        105220005
        36868297
        NLM18987864
        2010218177
        10.1007/s00330-008-1204-6
        NLM18987864
        105220005
      ppf: 1027
      ppct: 8
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: Dose reduction by automatic exposure control in multidetector computed tomography: comparison between measurement and calculation.
      aug:
        au:
          Lechel U
          Becker C
          Langenfeld-Jäger G
          Brix G
          Lechel, U
          Becker, C
          Langenfeld-Jäger, G
          Brix, G
        affil: Department of Medical Radiation Hygiene and Dosimetry, Federal Office for Radiation Protection, Neuherberg, Germany
      sug:
        subj:
          Tomography, X-Ray Computed Equipment and Supplies
          Tomography, X-Ray Computed Methods
          Algorithms
          Automation
          Body Burden
          Female
          Human
          Male
          Models, Theoretical
          Phantoms, Imaging
          Radiation Dosage
          Radiographic Image Interpretation, Computer-Assisted
          Radiometry Methods
          Radiotherapy, Computer-Assisted
          Radiation Monitoring Methods
          Female
          Male
      ab: The aim of this study was to investigate the potential of dose reduction in multidetector computed tomography (MDCT) by current-modulated automatic exposure control (AEC) and to test the reliability of the dose estimation by the conventional CT dosimetry program CT-EXPO, when an average tube current is used. Phantom measurements were performed at a CT system with 64 detector rows for four representative examination protocols, each without and with current-modulated AEC. Organ and effective doses were measured by thermoluminescence dosimeters (TLD) at an anthropomorphic Alderson phantom and compared with those given by the calculation with CT-EXPO. The application of AEC yielded dose reductions between 27 and 40% (TLD measurements). While good linearity was observed between measured and computed effective dose values both without and with AEC, the organ doses showed large deviations between measurement and calculation. The dose to patients undergoing a MDCT examination can be reduced considerably by applying a current-modulated AEC. Dosimetric algorithms using a constant current-time product provide reliable estimates of the effective dose.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N