Comparison of electrically evoked compound action potential thresholds and loudness estimates for the stimuli used to program the advanced bionics cochlear implant.

Background: In the mid-1990s, Cochlear Corporation introduced a cochlear implant (CI) to the market that was equipped with hardware that made it possible to record electrically evoked compound action potentials (ECAPs) from CI users of all ages. Over the course of the next decade, many studies were...

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of the American Academy of Audiology Vol. 21; no. 1; pp. 16 - 28
Autores principales: Jeon EK, Brown CJ, Etler CP, O'Brien S, Chiou L, Abbas PJ
Formato: research tables/charts Journal Article
Publicado: Thieme Medical Publishing Inc. Jan2010
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=105286264&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 105286264
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        10500545
        9OC
      jtl: Journal of the American Academy of Audiology
      issn: 10500545
      maglogo: Y
    pubinfo:
      dt: Jan2010
      vid: 21
      iid: 1
      pid: 2811
      pub: Thieme Medical Publishing Inc.
      place: New York, New York
    artinfo:
      ui:
        105286264
        47917290
        2010528880
        10.3766/jaaa.21.1.3
        NLM20085196
        105286264
      ppf: 16
      ppct: 12
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: Comparison of electrically evoked compound action potential thresholds and loudness estimates for the stimuli used to program the advanced bionics cochlear implant.
      aug:
        au:
          Jeon EK
          Brown CJ
          Etler CP
          O'Brien S
          Chiou L
          Abbas PJ
        affil: Department of Communication Sciences and Disorders, University of Iowa, Iowa City, IA 52242; eunkyung-jeon@uiowa.edu
      sug:
        subj:
          Evoked Potentials, Auditory
          Loudness Perception
          Adult
          Aged
          Aged, 80 and Over
          Bionics
          Cochlear Implant
          Descriptive Statistics
          Electric Stimulation
          Experimental Studies
          Female
          Funding Source
          Linear Regression
          Male
          Middle Age
          Paired T-Tests
          Prospective Studies
          Adult: 19-44 years
          Aged: 65+ years
          Aged, 80 & over
          Middle Aged: 45-64 years
          Female
          Male
      ab: Background: In the mid-1990s, Cochlear Corporation introduced a cochlear implant (CI) to the market that was equipped with hardware that made it possible to record electrically evoked compound action potentials (ECAPs) from CI users of all ages. Over the course of the next decade, many studies were published that compared ECAP thresholds with levels used to program the speech processor of the Nucleus CI. In 2001 Advanced Bionics Corporation introduced the Clarion CII cochlear implant (the Clarion CII internal device is also known as the CII Bionic Ear). This cochlear implant was also equipped with a system that allowed measurement of the ECAP. While a great deal is known about how ECAP thresholds compare with the levels used to program the speech processor of the Nucleus CI, relatively few studies have reported comparisons between ECAP thresholds and the levels used to program the speech processor of the Advanced Bionics CI. Purpose: To explore the relationship between ECAP thresholds and behavioral measures of perceptual dynamic range for the range of stimuli commonly used to program the speech processor of the Advanced Bionics CI. Research Design: This prospective and experimental study uses correlational and descriptive statistics to define the relationship between ECAP thresholds and perceptual dynamic range measures. Study Sample: Twelve postlingually deafened adults participated in this study. All were experienced users of the Advanced Bionics CI system. Data Collection and Analysis: ECAP thresholds were recorded using the commercially available SoundWave software. Perceptual measures of threshold (T-level), most comfortable level (M-level), and maximum comfortable level (C-level) were obtained using both 'tone bursts' and 'speech bursts.' The relationship between these perceptual and electrophysiological variables was defined using paired t-tests as well as correlation and linear regression. Results: ECAP thresholds were significantly correlated with the perceptual dynamic range measures studied; however, correlations were not strong. Analysis of the individual data revealed considerable discrepancy between the contour of ECAP threshold versus electrode function and the behavioral loudness estimates used for programming. Conclusion: ECAP thresholds recorded from Advanced Bionics cochlear implant users always indicated levels where the programming stimulus was audible for the listener. However, the correlation between ECAP thresholds and M-levels (the primary metric used to program the speech processor of the Advanced Bionics CI), while statistically significant, was quite modest. If programming levels are to be determined on the basis of ECAP thresholds, care should be taken to ensure that stimulation is not uncomfortably loud, particularly on the basal electrodes in the array.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N