TNRT profiles with the Nucleus Research Platform 8 system.

This study investigates the effect of the Nucleus CI24RE implant's neural response telemetry (NRT) system, which has less internal noise compared to its predecessor, the CI24M/R implant, on the NRT threshold (TNRT) profile across the array. CI24M/R measurements were simulated by ignoring CI24RE meas...

Descripción completa

Detalles Bibliográficos
Publicado en:International Journal of Audiology Vol. 48; no. 9; pp. 645 - 655
Autores principales: Lai WK, Dillier N, Weber BP, Lenarz T, Battmer R, Gantz B, Brown C, Cohen N, Waltzman S, Skinner M, Holden L, Cowan R, Busby P, Killian M
Formato: research tables/charts tracings Journal Article
Publicado: Taylor & Francis Ltd Sep2009
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=105328492&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 105328492
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        14992027
        JW2
      jtl: International Journal of Audiology
      issn: 14992027
      maglogo: Y
    pubinfo:
      dt: Sep2009
      vid: 48
      iid: 9
      pid: 377
      pub: Taylor & Francis Ltd
      place: Philadelphia, Pennsylvania
    artinfo:
      ui:
        105328492
        2010443151
        10.1080/14992020902962413
        NLM19513917
        105328492
      ppf: 645
      ppct: 10
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: TNRT profiles with the Nucleus Research Platform 8 system.
      aug:
        au:
          Lai WK
          Dillier N
          Weber BP
          Lenarz T
          Battmer R
          Gantz B
          Brown C
          Cohen N
          Waltzman S
          Skinner M
          Holden L
          Cowan R
          Busby P
          Killian M
        affil: Department of Otorhinolaryngology, University Hospital, Zürich, Switzerland
      sug:
        subj:
          Cochlear Implant
          Cochlear Implant Programming Evaluation
          Evoked Potentials, Auditory
          Signal Processing, Computer Assisted
          Telemetry
          Adult
          Aged
          Comparative Studies
          Descriptive Statistics
          Electrodes
          Equipment Design
          Factor Analysis
          Funding Source
          Middle Age
          Multicenter Studies
          Record Review
          Simulations
          Human
          Adult: 19-44 years
          Aged: 65+ years
          Middle Aged: 45-64 years
      ab: This study investigates the effect of the Nucleus CI24RE implant's neural response telemetry (NRT) system, which has less internal noise compared to its predecessor, the CI24M/R implant, on the NRT threshold (TNRT) profile across the array. CI24M/R measurements were simulated by ignoring CI24RE measurements with response amplitudes below 50 uV. Comparisons of the estimated TNRTs from the CI24RE measurements and the CI24M/R simulations suggest that, apart from a constant level difference, the TNRT profiles from the newer implant generally would not have differed very much from those of its predecessor. This view was also reflected by principal component analysis (PCA) results which revealed a 'shift' component similar to that reported by Smoorenburg et al (2002). On the whole, there is no indication that current practices of using the TNRT profiles for assisting with speech processor programming need to be revised for the CI24RE implant.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        tracings
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N