Quality-monitoring program for bar-code-assisted medication administration.
PURPOSE: The implementation of a quality-monitoring program that identifies and corrects problems associated with using a bar-code-assisted medication administration (BCMA) system is described. SUMMARY: In November 2004, the Bar Code Resource Office assembled a work group to develop a quality progra...
| Publicado en: | American Journal of Health-System Pharmacy Vol. 66; no. 12; pp. 1125 - 1132 |
|---|---|
| Autores principales: | , , , , |
| Formato: | algorithm tables/charts Journal Article |
| Publicado: |
Oxford University Press / USA
6/15/2009
|
| Acceso en línea: | Ver este registro en EBSCOhost |
| fields | @attributes: recordID: 1 pdfLink: plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=105363631&site=ehost-live header: @attributes: shortDbName: ccm uiTerm: 105363631 longDbName: CINAHL Complete uiTag: AN controlInfo: bkinfo: dissinfo: jinfo: jid: 10792082 1X3 jtl: American Journal of Health-System Pharmacy issn: 10792082 maglogo: N pubinfo: dt: 6/15/2009 vid: 66 iid: 12 pid: 622 pub: Oxford University Press / USA artinfo: ui: 105363631 2010321998 10.2146/ajhp080172 NLM19498130 105363631 ppf: 1125 ppct: 7 formats: fmt: @attributes: type: P tig: atl: Quality-monitoring program for bar-code-assisted medication administration. aug: au: Mims E Tucker C Carlson R Schneider R Bagby J affil: Department of Veterans Affairs, Bar Code Resource Office, Topeka, KS, USA. sug: subj: Bar Coding Utilization Medication Systems Program Implementation Quality Assurance Methods Bar Coding Standards Drug Packaging Standards Hospitals, Veterans Program Development Quality Control (Technology) Standards United States Department of Veterans Affairs Standards ab: PURPOSE: The implementation of a quality-monitoring program that identifies and corrects problems associated with using a bar-code-assisted medication administration (BCMA) system is described. SUMMARY: In November 2004, the Bar Code Resource Office assembled a work group to develop a quality program to improve machine-readable, bar-coded medications. The project scope involved the development of a pharmacy-based quality program for unit-dose packaging and bar-code labeling to improve the scanning success rate of bar-coded medications at the point-of-care. Data were collected from facility-based BCMA coordinators at each medical center regarding specific reasons for bedside scanning circumvention, as well as successful scan rates in the pharmacy and at the bedside. The pharmacy and bedside scanning data were aggregated and the baseline of successful scans was determined to be 95%. The reported reasons for scanning circumvention were grouped into six categories: bar-code labeling, missing doses, labels not scanning, error messages, mispackaged medications, and mislabeled medications. The work group developed strategies to mitigate problems in each of the areas. As a result of this effort, the Department of Veterans Affairs created a directive that outlined the best practices for unit-dose packaging and labeling, as well as requirements for ongoing data collection and reporting. CONCLUSION: A quality-monitoring program that identified and provided best-practice recommendations corrected problems associated with using a BCMA system and improved bar-code labeling processes. pubtype: Academic Journal doctype: algorithm tables/charts Journal Article ougenre: Article language: English refInfo: holdings: @attributes: islocal: N |
|---|