MR-guided liver biopsy within a short, wide-bore 1.5 Tesla MR system.

The purpose of this study was to evaluate the diagnostic efficacy of magnetic resonance (MR)-guided biopsy of focal liver lesions within a short, wide-bore 1.5-T MR system and to determine the duration and accuracy of needle placement using MR fluoroscopy guidance in 25 patients. Accuracy of needle...

Descripción completa

Detalles Bibliográficos
Publicado en:European Radiology Vol. 18; no. 12; pp. 2865 - 2874
Autores principales: Stattaus J, Maderwald S, Baba HA, Gerken G, Barkhausen J, Forsting M, Ladd ME, Stattaus, Joerg, Maderwald, Stefan, Baba, Hideo A, Gerken, Guido, Barkhausen, Joerg, Forsting, Michael, Ladd, Mark E
Formato: research Journal Article
Publicado: Springer Nature Dec2008
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=105570950&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 105570950
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        09387994
        NPH
      jtl: European Radiology
      issn: 09387994
      maglogo: N
    pubinfo:
      dt: Dec2008
      vid: 18
      iid: 12
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        105570950
        35166609
        NLM18641994
        2010095282
        10.1007/s00330-008-1088-5
        NLM18641994
        105570950
      ppf: 2865
      ppct: 9
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: MR-guided liver biopsy within a short, wide-bore 1.5 Tesla MR system.
      aug:
        au:
          Stattaus J
          Maderwald S
          Baba HA
          Gerken G
          Barkhausen J
          Forsting M
          Ladd ME
          Stattaus, Joerg
          Maderwald, Stefan
          Baba, Hideo A
          Gerken, Guido
          Barkhausen, Joerg
          Forsting, Michael
          Ladd, Mark E
        affil: Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, Hufelandstr. 55, 45122, Essen, Germany
      sug:
        subj:
          Biopsy, Needle Equipment and Supplies
          Liver Neoplasms Pathology
          Liver Pathology
          Magnetic Resonance Imaging Equipment and Supplies
          Therapy, Computer Assisted Equipment and Supplies
          Adult
          Aged
          Aged, 80 and Over
          Biopsy, Needle Methods
          Equipment Design
          Equipment Failure
          Female
          Magnetic Resonance Imaging Methods
          Male
          Middle Age
          Reproducibility of Results
          Sensitivity and Specificity
          Human
          Adult: 19-44 years
          Aged: 65+ years
          Aged, 80 & over
          Middle Aged: 45-64 years
          Female
          Male
      ab: The purpose of this study was to evaluate the diagnostic efficacy of magnetic resonance (MR)-guided biopsy of focal liver lesions within a short, wide-bore 1.5-T MR system and to determine the duration and accuracy of needle placement using MR fluoroscopy guidance in 25 patients. Accuracy of needle placement was evaluated in two orthogonal planes, and the out-of-plane angle of needle deflection was measured. Needle positioning was characterised subjectively as centred, peripheral, or exterior relative to the lesion. Exterior positioning was corrected by a step-by-step procedure. Surgical resection (n = 6), previous histologies (n = 8), or clinical/radiological follow-up (n = 11) served as the 'gold standard'. The guidance needle could be placed successfully using MR fluoroscopy in 20 of 25 patients (80%). Needle placement was rated as 'centred' in 11 and as 'peripheral' in nine patients. Median needle deflection was 2.6 degrees, with a median deviation of 3.4 mm. In five patients, the direct approach failed or was rated as 'exterior'; therefore, repositioning after needle stabilisation with a stainless-steel stylet was necessary. The diagnostic yield of all biopsies was: sensitivity 95.5%, specificity 100.0% and accuracy 96.0%. In conclusion, MR-guided biopsies in a short, wide-bore MR system yielded highly reliable biopsy results, and in most cases the direct approach with MR fluoroscopy guidance proved to be fast and accurate.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N