MRI of respiratory dynamics with 2D steady-state free-precession and 2D gradient echo sequences at 1.5 and 3 Tesla: an observer preference study.

To compare the image quality of dynamic lung MRI with variations of steady-state free-precession (SSFP) and gradient echo (GRE) cine techniques at 1.5 T and 3 T. Ventilated porcine lungs with simulated lesions inside a chest phantom and four healthy human subjects were assessed with SSFP (TR/TE=2.9/...

Descripción completa

Detalles Bibliográficos
Publicado en:European Radiology Vol. 19; no. 2; pp. 391 - 400
Autores principales: Fabel M, Wintersperger BJ, Dietrich O, Eichinger M, Fink C, Puderbach M, Kauczor HU, Schoenberg SO, Biederer J, Fabel, M, Wintersperger, B J, Dietrich, O, Eichinger, M, Fink, C, Puderbach, M, Kauczor, H-U, Schoenberg, S O, Biederer, J
Formato: research Journal Article
Publicado: Springer Nature Feb2009
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=105625000&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 105625000
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        09387994
        NPH
      jtl: European Radiology
      issn: 09387994
      maglogo: N
    pubinfo:
      dt: Feb2009
      vid: 19
      iid: 2
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        105625000
        36145965
        NLM18777025
        2010168297
        10.1007/s00330-008-1148-x
        NLM18777025
        105625000
      ppf: 391
      ppct: 9
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: MRI of respiratory dynamics with 2D steady-state free-precession and 2D gradient echo sequences at 1.5 and 3 Tesla: an observer preference study.
      aug:
        au:
          Fabel M
          Wintersperger BJ
          Dietrich O
          Eichinger M
          Fink C
          Puderbach M
          Kauczor HU
          Schoenberg SO
          Biederer J
          Fabel, M
          Wintersperger, B J
          Dietrich, O
          Eichinger, M
          Fink, C
          Puderbach, M
          Kauczor, H-U
          Schoenberg, S O
          Biederer, J
        affil: Department of Diagnostic Radiology, University Hospital Schleswig-Holstein, Campus Kiel, Arnold-Heller-Str. 9, 24105 Kiel, Germany
      sug:
        subj:
          Lung Pathology
          Magnetic Resonance Imaging Methods
          Respiratory System Pathology
          Adult
          Animal Studies
          Artifacts
          Contrast Media Pharmacodynamics
          Image Interpretation, Computer Assisted
          Observer Bias
          Phantoms, Imaging
          Reproducibility of Results
          Respiration
          Respiratory System Radiography
          Swine
          Time Factors
          Human
          Adult: 19-44 years
      ab: To compare the image quality of dynamic lung MRI with variations of steady-state free-precession (SSFP) and gradient echo (GRE) cine techniques at 1.5 T and 3 T. Ventilated porcine lungs with simulated lesions inside a chest phantom and four healthy human subjects were assessed with SSFP (TR/TE=2.9/1.22 ms; 3 ima/s) and GRE sequences (TR/TE=2.34/0.96 ms; 8 ima/s) as baseline at 1.5 and 3 T. Modified SSFPs were performed with nine to ten images/s (parallel imaging factors 2 and 3). Image quality for representative structures and artifacts was ranked by three observers independently. At 1.5 T, standard SSFP achieved the best image quality with superior spatial resolution and signal, but equal temporal resolution to GRE. SSFP with improved temporal resolution was ranked second best. Further acceleration (PI factor 3) was of no benefit, but increased artifacts. At 3 T, GRE outranged SSFP imaging with high lesion signal intensity, while artifacts on SSFP images increased visibly. At 1.5 T, a modified SSFP with moderate parallel imaging (PI factor 2) was considered the best compromise of temporal and spatial resolution. At 3 T, GRE sequences remain the best choice for dynamic lung MRI.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N