Accuracy of accelerated cine MR imaging at 3 Tesla in longitudinal follow-up of cardiac function.

The ability of fast, parallel-imaging-based cine magnetic resonance (MR) to monitor global cardiac function in longitudinal exams at 3 Tesla was evaluated. Seventeen patients with chronic cardiac disease underwent serial cine MR imaging exams (n=3) at 3 Tesla. Data were acquired in short-axis orient...

Descripción completa

Detalles Bibliográficos
Publicado en:European Radiology Vol. 18; no. 10; pp. 2095 - 2102
Autores principales: Sandner TA, Houck P, Runge VM, Sincleair S, Huber AM, Theisen D, Reiser MF, Wintersperger BJ, Sandner, Torleif A, Houck, Philip, Runge, Val M, Sincleair, Spencer, Huber, Armin M, Theisen, Daniel, Reiser, Maximilian F, Wintersperger, Bernd J
Formato: research Journal Article
Publicado: Springer Nature Oct2008
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=105626711&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 105626711
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        09387994
        NPH
      jtl: European Radiology
      issn: 09387994
      maglogo: N
    pubinfo:
      dt: Oct2008
      vid: 18
      iid: 10
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        105626711
        34227602
        NLM18463873
        2010157801
        10.1007/s00330-008-0993-y
        NLM18463873
        105626711
      ppf: 2095
      ppct: 7
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: Accuracy of accelerated cine MR imaging at 3 Tesla in longitudinal follow-up of cardiac function.
      aug:
        au:
          Sandner TA
          Houck P
          Runge VM
          Sincleair S
          Huber AM
          Theisen D
          Reiser MF
          Wintersperger BJ
          Sandner, Torleif A
          Houck, Philip
          Runge, Val M
          Sincleair, Spencer
          Huber, Armin M
          Theisen, Daniel
          Reiser, Maximilian F
          Wintersperger, Bernd J
        affil: Department of Clinical Radiology, University Hospitals-Campus Grosshadern, Ludwig-Maximilians-University, Marchioninistr. 15, 81377 Munich, Germany
      sug:
        subj:
          Diagnostic Imaging Methods
          Magnetic Resonance Imaging Methods
          Ventricular Dysfunction, Left Diagnosis
          Adult
          Aged
          Aged, 80 and Over
          Female
          Male
          Middle Age
          Prospective Studies
          Reproducibility of Results
          Sensitivity and Specificity
          Stroke Volume
          Human
          Adult: 19-44 years
          Aged: 65+ years
          Aged, 80 & over
          Middle Aged: 45-64 years
          Female
          Male
      ab: The ability of fast, parallel-imaging-based cine magnetic resonance (MR) to monitor global cardiac function in longitudinal exams at 3 Tesla was evaluated. Seventeen patients with chronic cardiac disease underwent serial cine MR imaging exams (n=3) at 3 Tesla. Data were acquired in short-axis orientation using cine steady-state free precession (SSFP) with a spatial resolution of 2.5 x 1.9 mm(2) at 45 ms temporal resolution. Multislice imaging (three slices/breath-hold) was performed using TSENSE acceleration (R=3) and standard single-slice cine (non-TSENSE) was performed at identical locations in consecutive breath-holds. End-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF) and myocardial mass (MM) of both cine approaches were compared for individual time-points as well as for longitudinal comparison. TSENSE-cine did not show significant differences for EDV (2.6 ml; P=0.79), ESV (2.2 ml; P=0.81), EF (-0.3%; P=0.95) and MM (2.4 g; P=0.72) in comparison with non-TSENSE. Longitudinal ANOVA analysis did not reveal significant differences for any parameter, neither for non-TSENSE data (all P>0.7) nor for TSENSE data (all P>0.9). Multifactorial ANOVA showed non-significant differences (all P>0.7) at comparable data variances. Data acquisition was significantly shortened using TSENSE. Threefold accelerated multislice cine at 3 Tesla allows accurate assessment of volumetric LV data and accurate longitudinal monitoring of global LV function at a substantially shorter overall examination time.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N