Reliability of performance-based measures in people awaiting joint replacement surgery of the hip or knee.

Background and Purpose. Understanding the reliability of selected measurement tools is a prerequisite to understanding the effects of clinical interventions. The aim of this investigation was to determine the reliability of the 50-Foot Timed Walk (50 FTW) and 30-second Chair Stand Test (30 CST) in s...

Descripción completa

Detalles Bibliográficos
Publicado en:Physiotherapy Research International Vol. 13; no. 3; pp. 141 - 153
Autores principales: Gill S, McBurney H
Formato: research tables/charts Journal Article
Publicado: Wiley-Blackwell Sep2008
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=105704536&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 105704536
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        13582267
        GPG
      jtl: Physiotherapy Research International
      issn: 13582267
      maglogo: Y
    pubinfo:
      dt: Sep2008
      vid: 13
      iid: 3
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        105704536
        2010029309
        10.1002/pri.411
        NLM18697226
        105704536
      ppf: 141
      ppct: 12
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Reliability of performance-based measures in people awaiting joint replacement surgery of the hip or knee.
      aug:
        au:
          Gill S
          McBurney H
        affil: La Trobe University, Australia
      sug:
        subj:
          Arthroplasty, Replacement
          Clinical Assessment Tools
          Functional Assessment Methods
          Instrument Validation
          Preoperative Period
          Aged
          Analysis of Variance
          Arthroplasty, Replacement, Hip
          Arthroplasty, Replacement, Knee
          Australia
          Clinical Assessment Tools Methods
          Confidence Intervals
          Data Analysis Software
          Descriptive Statistics
          Female
          Funding Source
          Interrater Reliability
          Intraclass Correlation Coefficient
          Intrarater Reliability
          Male
          Post Hoc Analysis
          Protocols
          Repeated Measures
          Rising Evaluation
          T-Tests
          Validation Studies
          Walking Evaluation
          Human
          Aged: 65+ years
          Female
          Male
      ab: Background and Purpose. Understanding the reliability of selected measurement tools is a prerequisite to understanding the effects of clinical interventions. The aim of this investigation was to determine the reliability of the 50-Foot Timed Walk (50 FTW) and 30-second Chair Stand Test (30 CST) in subjects awaiting joint replacement surgery of the hip or knee. Methods. Eighty-two subjects participating in a 6-week exercise programme were assessed at baseline, 7 weeks and 15 weeks. Four trials of the 50 FTW and two trials of the 30 CST were completed at each assessment. Eleven trained assessors completed the assessments. Results. Intra-class correlations were consistently high for the 50 FTW and 30 CST at all assessments. At the baseline assessment, trial 1 was found to be significantly different from subsequent trials for both the 50 FTW and 30 CST. This effect was not evident at the 7-week and 15-week assessments. At the baseline assessment, scores for the 50 FTW became stable after the first trial. Estimates of minimum detectable change indicated that participants needed to change by more than 3.08 seconds and 1.64 stands to be 90% confident that a real change had occurred for the 50 FTW and 30 CST, respectively. Conclusion. The 50 FTW and 30 CST can be reliable measures of physical performance. However, because we found a practice effect at the baseline assessment, a practice trial should be allowed before data collection begins. Because only two trials of the 30 CST were completed, further research is required to confirm whether scores at the initial assessment become stable on repeated testing. Copyright © 2008 John Wiley & Sons, Ltd.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N