Clinical performance of the implantable cardioverter defibrillator: electrocardiographic documentation of 101 spontaneous discharges.

Records of 105 patients, who received an automatic implantable cardioverter defibrillator (AICD), were studied to investigate the causes of spontaneous AICD discharges and to correlate the symptoms with the arrhythmias triggering AICD discharges. During a follow-up period of 13 ± 8 months, 46/105 (4...

Descripción completa

Detalles Bibliográficos
Publicado en:Pacing & Clinical Electrophysiology Vol. 14; no. 2; pp. 280 - 286
Autores principales: Maloney J, Masterson M, Khoury D, Trohman R, Wilkoff B, Simmons T, Morant V, Castle L
Formato: Journal Article
Publicado: Wiley-Blackwell Feb1991
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106034551&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 106034551
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        01478389
        4F8
      jtl: Pacing & Clinical Electrophysiology
      issn: 01478389
      maglogo: Y
    pubinfo:
      dt: Feb1991
      vid: 14
      iid: 2
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        106034551
        2009407514
        NLM1706831
        106034551
      ppf: 280
      ppct: 6
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Clinical performance of the implantable cardioverter defibrillator: electrocardiographic documentation of 101 spontaneous discharges.
      aug:
        au:
          Maloney J
          Masterson M
          Khoury D
          Trohman R
          Wilkoff B
          Simmons T
          Morant V
          Castle L
      sug:
      ab: Records of 105 patients, who received an automatic implantable cardioverter defibrillator (AICD), were studied to investigate the causes of spontaneous AICD discharges and to correlate the symptoms with the arrhythmias triggering AICD discharges. During a follow-up period of 13 ± 8 months, 46/105 (44%) patients had 566 spontaneous AICD discharges. A total of 101 discharges were documented with Halter monitoring in 23 patients. In this study group, there were 8 (8%) AICD discharges for 5 episodes of ventricular fibrillation, and 68 (67%) discharges for 63 episodes of sustained ventricular tachycardia. Patients lost consciousness in all episodes of ventricular fibrillation, but were symptomatic prior to only 36 (53%) discharges in ventricular tachycardia. Nonsustained ventricular tachycardia persisting for a period of 7.5 ± 2 seconds resulted in 20 AICD discharges; patients were symptomatic prior to 13 (65%) discharges. Supraventricular tachycardias triggered three discharges. One patient had two spurious discharges during sinus rhythm. In conclusion, most of the spontaneous AICD discharges were appropriate for the detected rhythms, but only clinically appropriate for the management of arrhythmias in 75% of the cases. A significant portion of the patients with sustained or nonsustained ventricular tachycardias triggering AICD discharges were asymptomatic prior to discharge, which requires further assessment of the physiology of the arrhythmia as a component of the detection algorithm.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N