Differentiation of Arrhythmias by Measurement of Intracardiac Pressures in Man.

Antitachycardia devices currently use sustained high rate, abrupt changes in cycle length, and probability density function to determine the onset of ventricular tachycardia. Hemodynamic changes occur with the onset of tachycardia and may provide a method of discriminating supraventricular from vent...

Full description

Bibliographic Details
Published in:Pacing & Clinical Electrophysiology Vol. 14; no. 2; pp. 161 - 168
Main Authors: Beauregard LM, Volosin KJ, Waxman HL
Format: Journal Article
Published: Wiley-Blackwell Feb1991
Online Access:View this record in EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106034716&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 106034716
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        01478389
        4F8
      jtl: Pacing & Clinical Electrophysiology
      issn: 01478389
      maglogo: Y
    pubinfo:
      dt: Feb1991
      vid: 14
      iid: 2
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        106034716
        2009407886
        NLM1706500
        106034716
      ppf: 161
      ppct: 7
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Differentiation of Arrhythmias by Measurement of Intracardiac Pressures in Man.
      aug:
        au:
          Beauregard LM
          Volosin KJ
          Waxman HL
      sug:
      ab: Antitachycardia devices currently use sustained high rate, abrupt changes in cycle length, and probability density function to determine the onset of ventricular tachycardia. Hemodynamic changes occur with the onset of tachycardia and may provide a method of discriminating supraventricular from ventricular tachycardia. In this study, patients had atrial and ventricular pressures measured during rapid atrial and ventricular pacing. Right atrial pressure increased significantly with ventricular pacing but not with atrial pacing, flight ventricular pressures did not significantly differ with atrial or ventricular pacing. The change in atrial pressure compared to baseline was greater, with ventricular pacing compared to atrial pacing. Right ventricular pressure increased compared to baseline with atrial or ventricular pacing, but there was no significant difference between pacing modalities. Measurement of right atrial pressure might prove useful in discriminating supraventricular from ventricular tachycardia.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N