Automatic implantable cardioverter-defibrillator structural characteristics.

There are a number of equipment options and surgical techniques available for automatic implantable cardioverter- defibrillator implantation. The system can be successfully used even in problem cases where restrictions may be imposed because of physical build or the presence of other implanted devic...

Full description

Bibliographic Details
Published in:Pacing & Clinical Electrophysiology Vol. 7; no. 6; pp. 1331 - 1338
Main Authors: Mower MM, Reid PR, Watkins L Jr., Griffith LS, Platia EV, Bach SM Jr., Imran M, Juanteguy JM, Mirowski M
Format: Journal Article
Published: Wiley-Blackwell Nov1984
Online Access:View this record in EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106034828&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 106034828
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        01478389
        4F8
      jtl: Pacing & Clinical Electrophysiology
      issn: 01478389
      maglogo: Y
    pubinfo:
      dt: Nov1984
      vid: 7
      iid: 6
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        106034828
        2009408006
        NLM6209679
        106034828
      ppf: 1331
      ppct: 7
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Automatic implantable cardioverter-defibrillator structural characteristics.
      aug:
        au:
          Mower MM
          Reid PR
          Watkins L Jr.
          Griffith LS
          Platia EV
          Bach SM Jr.
          Imran M
          Juanteguy JM
          Mirowski M
      sug:
      ab: There are a number of equipment options and surgical techniques available for automatic implantable cardioverter- defibrillator implantation. The system can be successfully used even in problem cases where restrictions may be imposed because of physical build or the presence of other implanted devices. The sensing requirements and energy output of the units can be tailored to the exact needs of the particular patient. Battery life and device function are easily monitored periodically following implantation, making possible elective replacement of the pulse generator when the batteries became depleted.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N