A three-dimensional display for cardiac activation mapping.

A three-dimensional display is described that allows activation sequences from the epicardium and endocardium to be shown simultaneously on the same image. Three electrode arrays (epicardial sock, left ventricular balloon, right ventricular balloon are represented in a three-dimensional perspective...

Descripción completa

Detalles Bibliográficos
Publicado en:Pacing & Clinical Electrophysiology Vol. 14; no. 4; pp. 538 - 546
Autores principales: Massé S, Sevaptsidis E, Parson ID, Downar E
Formato: Journal Article
Publicado: Wiley-Blackwell Apr1991
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106034979&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 106034979
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        01478389
        4F8
      jtl: Pacing & Clinical Electrophysiology
      issn: 01478389
      maglogo: Y
    pubinfo:
      dt: Apr1991
      vid: 14
      iid: 4
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        106034979
        2009408265
        NLM1710059
        106034979
      ppf: 538
      ppct: 8
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: A three-dimensional display for cardiac activation mapping.
      aug:
        au:
          Massé S
          Sevaptsidis E
          Parson ID
          Downar E
      sug:
      ab: A three-dimensional display is described that allows activation sequences from the epicardium and endocardium to be shown simultaneously on the same image. Three electrode arrays (epicardial sock, left ventricular balloon, right ventricular balloon are represented in a three-dimensional perspective by an array of dots that are intensified when activated. This arrangement requires fewer calculations and is easier to interpret than sliced-isochronal maps but cannot represent a complete heart cycle in one image. The three-dimensional display eliminates the distortion caused by two-dimensional diagrams and facilitates activation correlation between electrode arrays. A standard, low cost microcomputer has been used to implement the activation display.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N