Spatial resolution and role of pacemapping during ablation of accessory pathways.

The objectives of this study were: (1) to evaluate quantitatively the spatial resolution of pacemapping: and (2) to assess the predictive value and role of pacemapping for the catheter ablation of overt APs. Sixtythree unipolar leads were used instead of the standard 12-lead ECG to acquire more info...

Descripción completa

Detalles Bibliográficos
Publicado en:Pacing & Clinical Electrophysiology Vol. 20; no. 3; pp. 683 - 695
Autores principales: Molin F, Savard P, Dubuc M, Kus T, Tremblay G, Nadeau R
Formato: Journal Article
Publicado: Wiley-Blackwell Mar1997
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106036867&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 106036867
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        01478389
        4F8
      jtl: Pacing & Clinical Electrophysiology
      issn: 01478389
      maglogo: Y
    pubinfo:
      dt: Mar1997
      vid: 20
      iid: 3
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        106036867
        106036867
        2009411480
        10.1111/j.1540-8159.1997.tb03887.x
        106036867
      ppf: 683
      ppct: 12
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Spatial resolution and role of pacemapping during ablation of accessory pathways.
      aug:
        au:
          Molin F
          Savard P
          Dubuc M
          Kus T
          Tremblay G
          Nadeau R
      sug:
      ab: The objectives of this study were: (1) to evaluate quantitatively the spatial resolution of pacemapping: and (2) to assess the predictive value and role of pacemapping for the catheter ablation of overt APs. Sixtythree unipolar leads were used instead of the standard 12-lead ECG to acquire more information and assess the intrinsic accuracy of pacemapping. Spatial resolution was evaluated in 19 patients for whom data were recorded during bipolar ventricular pacing near the AV ring using the three electrode pairs of a quadripolar ablation catheter with a 5-mm interelectrode spacing. The predictive value was assessed in 27 patients with overt APs who underwent HF ablation: their data were recorded during pacing at the site of successful ablation and at one or two sites where HF energy delivery was ineffective. Data from different beats were compared visually by using body surface potential maps and quantitatively by computing average correlation coefficients (r). Reproducibility was high for paced beats (r = 0.98 ± 0.02). Displacements of 5 mm of the pacing site could be detected with a sensitivity of 90% and a specificity of 87%. Correlation between pacing at successful ablation sites and preexcited sinus rhythm was low (r = 0.79 ± 0.11) and the ablation outcome could be predicted with a negative prediction accuracy of 87% and a positive prediction accuracy of 49%. Despite an excellent spatial resolution, pacemapping is of limited value for the identification of successful AP ablation sites, probably because APs can be interrupted at some distance from their ventricular insertion point.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N