Usefulness of 1-hour and 24-hour heart rate holter inbuilt in new tx rate adaptive pacemakers.

The rate adaptive TX* pacemaker uses the evoked QT interval as an indicator of physiological demand. In order to obtain a rate adaptation close to physiological patterns we used in the past, in each patient, on the slope value and/or the T wave sensing window, controlling via exercise stress testing...

Descripción completa

Detalles Bibliográficos
Publicado en:Pacing & Clinical Electrophysiology Vol. 13; no. 12; pp. 1751 - 1755
Autores principales: Sermasi S, Marconi M, Marzaloni M
Formato: Journal Article
Publicado: Wiley-Blackwell Dec1990
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106038061&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 106038061
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        01478389
        4F8
      jtl: Pacing & Clinical Electrophysiology
      issn: 01478389
      maglogo: Y
    pubinfo:
      dt: Dec1990
      vid: 13
      iid: 12
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        106038061
        2009413852
        NLM1704535
        106038061
      ppf: 1751
      ppct: 4
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Usefulness of 1-hour and 24-hour heart rate holter inbuilt in new tx rate adaptive pacemakers.
      aug:
        au:
          Sermasi S
          Marconi M
          Marzaloni M
      sug:
      ab: The rate adaptive TX* pacemaker uses the evoked QT interval as an indicator of physiological demand. In order to obtain a rate adaptation close to physiological patterns we used in the past, in each patient, on the slope value and/or the T wave sensing window, controlling via exercise stress testing and Holier the results achieved. It was an expensive method, but the system produced effective rate responsive pacing. The new series of TX* pacemakers (Quintech 919 and Rhythmyx), beside the dynamic slope feature, are equipped with a 1-hour heart rate Holter (HRH) that can he used during effort without the need for manually recording the heart rate. In this mode TX* pacemakers calculate the average heart rate over 20-second periods and stores the values continuously for 1 hour. In addition, a 24-hour HRH is available, which calculates the average heart rate over 7.5-minute periods. showing heart rate trend during the last day prior to interrogation. Each HRH can he accessed by the programmer and printed out. Using four Quintech 919* and five Rhythmyx units, the inbuilt HRH proved its utility by making the heart rate adaptation checking procedure easier, faster, and more economic.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N