Holter, loop recorder, and event counter capabilities of implanted devices.

The current generation of cardiac pacemakers and implantable cardioverter defibrillators almost all have some capabilities to store data regarding device activity and patient events for future retrieval. This information may provide valuable information regarding device function and whether this is...

Descripción completa

Detalles Bibliográficos
Publicado en:Pacing & Clinical Electrophysiology Vol. 20; no. 10; pp. 2658 - 2670
Autores principales: Waktare JE, Malik M
Formato: Journal Article
Publicado: Wiley-Blackwell Oct1997
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106038985&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 106038985
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        01478389
        4F8
      jtl: Pacing & Clinical Electrophysiology
      issn: 01478389
      maglogo: Y
    pubinfo:
      dt: Oct1997
      vid: 20
      iid: 10
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        106038985
        2009415419
        106038985
      ppf: 2658
      ppct: 12
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Holter, loop recorder, and event counter capabilities of implanted devices.
      aug:
        au:
          Waktare JE
          Malik M
      sug:
      ab: The current generation of cardiac pacemakers and implantable cardioverter defibrillators almost all have some capabilities to store data regarding device activity and patient events for future retrieval. This information may provide valuable information regarding device function and whether this is proving valuable in patient management. Examples include 'pace-sense' counters, which can reveal under sensing of patient events, and serial lead impedance measurements, which are able to demonstrate trends not seen on isolated measurements. Holter capabilities become vital in more advanced devices for documenting the utility of, and fine tuning the programming of, features such as anti tachycardia pacing, rate-responsiveness, and mode-switching. Finally, the ability to store patient events as marker channels and even intracardiac electrograms adds a diagnostic capability not available through external monitoring. This role has now been advanced by the development of a purely diagnostic implantable loop recorder.
      pubtype: Academic Journal