Activation time detection algorithms used in computerized intraoperative cardiac mapping: a comparison with manually determined activation tunes.

Introduction: Local activation determined from monopolar electrograms usually is marked at the time of the minimum slope. In bipolar recordings, the peak, the maximum absolute slope, the baseline crossing of the segment containing the maximum absolute slope and morphological criteria have been used....

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of Cardiovascular Electrophysiology Vol. 2; no. 5; pp. 388 - 398
Autores principales: Pieper CF, Blue R, Pacifico A
Formato: Journal Article
Publicado: Wiley-Blackwell Oct1991
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106040617&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 106040617
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        10453873
        GSB
      jtl: Journal of Cardiovascular Electrophysiology
      issn: 10453873
      maglogo: Y
    pubinfo:
      dt: Oct1991
      vid: 2
      iid: 5
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        106040617
        2009419354
        106040617
      ppf: 388
      ppct: 10
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Activation time detection algorithms used in computerized intraoperative cardiac mapping: a comparison with manually determined activation tunes.
      aug:
        au:
          Pieper CF
          Blue R
          Pacifico A
      sug:
      ab: Introduction: Local activation determined from monopolar electrograms usually is marked at the time of the minimum slope. In bipolar recordings, the peak, the maximum absolute slope, the baseline crossing of the segment containing the maximum absolute slope and morphological criteria have been used. The purpose of this work is: (1) to compare activation times determined using these algorithms with activation times corrected by electrophysiologists; and (2) to determine which computerized algorithm requires fewest operator correction of outliers. Methods and Results: Monopolar and bipolar electrograms were collected from the epicardium of subjects undergoing surgery for ventricular tachycardia and Wolff-Parkinson-White syndrome, and the above bipolar and monopolar algorithms were evaluated. The electrophysiologists viewed adjacent channels and evolving isochronal maps but not the computer markings. The morphological algorithm compared most favorably with times marked up by electrophysiologists having an overall average difference of 2.2 ±3.1 msec. For monopolar data, a five point, least square fit, second-order slope approximation algorithm most closely agreed with the electrophysiologist corrected algorithm (3.2± 4.0 msec). the morphological and least square algorithms also produced the fewest outliers (3.1 % and 5.7%, respectively). When outliers were removed, bipolar and monopolar discrepancies were reduced to 1.8 ± 1.9 and 2.5 ± 2.3 msec, respectively. Conclusions: Thus, among those algorithms tested, an algorithm based on morphological criteria is best suited for computer determination of bipolar activation times and compares favorably to variations between electrophysiologist corrected and computer marked activation times determined traditionally by the largest negative slope in monopolar data. Identification of outliers using contextual and improved morphological algorithms may improve computerized mapping system performance.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N