Tachycardia recognition and diagnosis from changes in right atrial pressure waveform--a feasibility study.

Implantable defibrillators either monitor heart rate or use a probability density function to detect ventricular fibrillation/tachycardia. As a result, they are unable to discriminate sinus tachycardia and atrial arrhythmias from malignant ventricular rhythms. We have assessed high fidelity fiber-op...

Descripción completa

Detalles Bibliográficos
Publicado en:Pacing & Clinical Electrophysiology Vol. 14; no. 9; pp. 1384 - 1393
Autores principales: Kaye GC, Astridge P, Perrins J
Formato: research Journal Article
Publicado: Wiley-Blackwell Sep1991
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106085849&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 106085849
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        01478389
        4F8
      jtl: Pacing & Clinical Electrophysiology
      issn: 01478389
      maglogo: Y
    pubinfo:
      dt: Sep1991
      vid: 14
      iid: 9
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        106085849
        2009409610
        10.1111/j.1540-8159.1991.tb02884.x
        NLM1720532
        106085849
      ppf: 1384
      ppct: 9
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Tachycardia recognition and diagnosis from changes in right atrial pressure waveform--a feasibility study.
      aug:
        au:
          Kaye GC
          Astridge P
          Perrins J
      sug:
        subj:
          Cardiovascular System Physiology
          Heart Catheterization Equipment and Supplies
          Tachycardia Diagnosis
          Tachycardia, Supraventricular Diagnosis
          Adult
          Atrial Fibrillation Diagnosis
          Atrial Flutter Diagnosis
          Cardiac Pacing, Artificial
          Equipment Design
          Female
          Information Science
          Male
          Pacemaker, Artificial
          Pilot Studies
          Pressure
          Human
          Adult: 19-44 years
          Female
          Male
      ab: Implantable defibrillators either monitor heart rate or use a probability density function to detect ventricular fibrillation/tachycardia. As a result, they are unable to discriminate sinus tachycardia and atrial arrhythmias from malignant ventricular rhythms. We have assessed high fidelity fiber-optic pressure recordings in the right atrium during cardiac arrhythmias in 23 patients [mean age 44 years, 11 females) undergoing electrophysiological study. The unfiltered pressure signal was amplified and recorded on paper. During sinus rhythm, a constant amplitude deflection occurred during atrial systole (a wave). A characteristic waveform pattern was observed during each of the studied tachyarrhythmias, which included atrial flutter and fibrillation, atrioventricular nodal reentrant tachycardia, atrioventricular reentrant tachycardia, and ventricular tachycardia with and without ventriculoatrial conduction. The waveform pattern allowed clear visual discrimination of the underlying arrhythmia. Mean atrial pressure was increased during all arrhythmias and did not allow discrimination of the nature of the tachycardia. High fidelity pressure recordings produced characteristic appearances for pattern recognition of each arrhythmia studied. They allowed determination of the temporal relation between electrical and mechanical cardiac events and may have potential in the detection and recognition of cardiac arrhythmias.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N