Instrumentation for the Follow-Up of Pacemade Patients.

Logic circuitry has been added to an electrocardiogram telephone transmitter. It processes the electrocardiogram and permits frequent self-checks by the patient on rate, capture and sensing function of an im planted demand pulse generator system. Correct function is communicated to the patient by a...

Descripción completa

Detalles Bibliográficos
Publicado en:Pacing & Clinical Electrophysiology Vol. 2; no. 3; pp. 315 - 325
Autores principales: Federico AJ, Giori F, Bhayana JN, Chardack WM, Michalek S
Formato: Journal Article
Publicado: Wiley-Blackwell May1979
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106086196&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 106086196
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        01478389
        4F8
      jtl: Pacing & Clinical Electrophysiology
      issn: 01478389
      maglogo: Y
    pubinfo:
      dt: May1979
      vid: 2
      iid: 3
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        106086196
        106086196
        2009410439
        10.1111/j.1540-8159.1979.tb03651.x
        NLM95296
        106086196
      ppf: 315
      ppct: 10
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Instrumentation for the Follow-Up of Pacemade Patients.
      aug:
        au:
          Federico AJ
          Giori F
          Bhayana JN
          Chardack WM
          Michalek S
      sug:
        subj:
          Electrocardiography Methods
          Monitoring, Physiologic Methods
          Pacemaker, Artificial
          Telephone
          Logic
          Self Care
      ab: Logic circuitry has been added to an electrocardiogram telephone transmitter. It processes the electrocardiogram and permits frequent self-checks by the patient on rate, capture and sensing function of an im planted demand pulse generator system. Correct function is communicated to the patient by a green light. Malfunction with regard to any of these parameters produces an irreversible yellow light signaling the patient to contact his physician. The self-check is reassuring to the patient during intervals between visits to the physician's office or a specialized clinic. The system, at present, is applicable only to demand pulse generators with a high magnet test rate (90 ppm or higher) which assures capture in virtually all patients. This and other limitations are discussed. Their incidence is low, some can be remedied and in the majority of patients they do not impair the clinical usefulness of the system.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N