Instrumentation for the Follow-Up of Pacemade Patients.
Logic circuitry has been added to an electrocardiogram telephone transmitter. It processes the electrocardiogram and permits frequent self-checks by the patient on rate, capture and sensing function of an im planted demand pulse generator system. Correct function is communicated to the patient by a...
| Publicado en: | Pacing & Clinical Electrophysiology Vol. 2; no. 3; pp. 315 - 325 |
|---|---|
| Autores principales: | , , , , |
| Formato: | Journal Article |
| Publicado: |
Wiley-Blackwell
May1979
|
| Acceso en línea: | Ver este registro en EBSCOhost |
| fields | @attributes: recordID: 1 pdfLink: plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106086196&site=ehost-live header: @attributes: shortDbName: ccm uiTerm: 106086196 longDbName: CINAHL Complete uiTag: AN controlInfo: bkinfo: dissinfo: jinfo: jid: 01478389 4F8 jtl: Pacing & Clinical Electrophysiology issn: 01478389 maglogo: Y pubinfo: dt: May1979 vid: 2 iid: 3 pid: 480 pub: Wiley-Blackwell place: Malden, Massachusetts artinfo: ui: 106086196 106086196 2009410439 10.1111/j.1540-8159.1979.tb03651.x NLM95296 106086196 ppf: 315 ppct: 10 formats: fmt: @attributes: type: P tig: atl: Instrumentation for the Follow-Up of Pacemade Patients. aug: au: Federico AJ Giori F Bhayana JN Chardack WM Michalek S sug: subj: Electrocardiography Methods Monitoring, Physiologic Methods Pacemaker, Artificial Telephone Logic Self Care ab: Logic circuitry has been added to an electrocardiogram telephone transmitter. It processes the electrocardiogram and permits frequent self-checks by the patient on rate, capture and sensing function of an im planted demand pulse generator system. Correct function is communicated to the patient by a green light. Malfunction with regard to any of these parameters produces an irreversible yellow light signaling the patient to contact his physician. The self-check is reassuring to the patient during intervals between visits to the physician's office or a specialized clinic. The system, at present, is applicable only to demand pulse generators with a high magnet test rate (90 ppm or higher) which assures capture in virtually all patients. This and other limitations are discussed. Their incidence is low, some can be remedied and in the majority of patients they do not impair the clinical usefulness of the system. pubtype: Academic Journal doctype: Journal Article ougenre: Article language: English refInfo: holdings: @attributes: islocal: N |
|---|