The sock electrode array: a tool for determining global epicardial activation during unstable arrhythmias.

The conventional technique for mapping the sequence of epicardial activation uses a hand-held electrode mover) over the heart to record from a number of epicardial sites one at a time, and requires 5-15 minutes to record from 50 or more sites distributed over the entire ventricular epicardium. This...

Descripción completa

Detalles Bibliográficos
Publicado en:Pacing & Clinical Electrophysiology Vol. 3; no. 5; pp. 531 - 541
Autores principales: Harrison L, Ideker RE, Smith WM, Klein GJ, Kasell J, Wallace AG, Gallagher JJ
Formato: Journal Article
Publicado: Wiley-Blackwell Sep1980
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106086208&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 106086208
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        01478389
        4F8
      jtl: Pacing & Clinical Electrophysiology
      issn: 01478389
      maglogo: Y
    pubinfo:
      dt: Sep1980
      vid: 3
      iid: 5
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        106086208
        2009410464
        NLM6160551
        106086208
      ppf: 531
      ppct: 10
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: The sock electrode array: a tool for determining global epicardial activation during unstable arrhythmias.
      aug:
        au:
          Harrison L
          Ideker RE
          Smith WM
          Klein GJ
          Kasell J
          Wallace AG
          Gallagher JJ
      sug:
        subj:
          Arrhythmia Physiopathology
          Electrodes
          Electrophysiology Equipment and Supplies
          Heart Physiopathology
          Animals
          Cardiac Pacing, Artificial
          Computers and Computerization
          Data Display
          Dogs
          Heart Physiology
          Time Factors
      ab: The conventional technique for mapping the sequence of epicardial activation uses a hand-held electrode mover) over the heart to record from a number of epicardial sites one at a time, and requires 5-15 minutes to record from 50 or more sites distributed over the entire ventricular epicardium. This method is inadequate for arrhythmias that are transient or vary from beat to beat. To overcome these limitations the 'sock electrode array' a contour-fitting sock containing 26 or 52 electrodes, has been developed. The nylon mesh sock is pulled over the heart and permits simultaneous recording of potentials from electrodes distributed over the entire ventricular epicardium. The electro- grams are recorded and converted to digital form for computer generation of isochronous maps. Maps of the epicardial activation sequence derived from the sock electrode were compared to those obtained by the hand-held electrode in six normal dogs during sinus rhythm and ventricular pacing. The sequence of local activation times acquired by both methods showed similar areas of early and late activation and comparable isochronous maps. The hand-held electrode technique required 10- 15 minutes for data acquisition and another 15-30 minutes for analysis. The sock electrode array allowed electrograms from 26 epicardial electrodes to he recorded simultaneously during one cardiac cycle and computer generated isochronous mops could be displayed within 10 minutes. This method allows rapid recording and analysis of epicardial electrical phenomena and should meet the time constraints imposed during the intraoperative study of ventricular tachyarrhythmias in patients.