Augmented two-channel arrhythmia detection: an efficient diagnostic method for implantable devices.
ICDs are highly effective in preventing sudden cardiac death. However, inappropriate device shocks caused by false-positive diagnoses are estimated to happen in 20% of all patients. The need for implantable electrical devices to detect with precision arrhythmias requiring therapy has spawned a varie...
| Published in: | Pacing & Clinical Electrophysiology Vol. 19; no. 10; pp. 1493 - 1502 |
|---|---|
| Main Authors: | , , , , |
| Format: | Journal Article |
| Published: |
Wiley-Blackwell
Oct1996
|
| Online Access: | View this record in EBSCOhost |
| fields | @attributes: recordID: 1 pdfLink: plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106086338&site=ehost-live header: @attributes: shortDbName: ccm uiTerm: 106086338 longDbName: CINAHL Complete uiTag: AN controlInfo: bkinfo: dissinfo: jinfo: jid: 01478389 4F8 jtl: Pacing & Clinical Electrophysiology issn: 01478389 maglogo: Y pubinfo: dt: Oct1996 vid: 19 iid: 10 pid: 480 pub: Wiley-Blackwell place: Malden, Massachusetts artinfo: ui: 106086338 106086338 2009411129 10.1111/j.1540-8159.1996.tb03164.x NLM8904542 106086338 ppf: 1493 ppct: 9 formats: fmt: @attributes: type: P tig: atl: Augmented two-channel arrhythmia detection: an efficient diagnostic method for implantable devices. aug: au: Chiang CJ Jenkins JM Caswell SA Stevenson SA Dicarlo LA sug: subj: Arrhythmia Diagnosis Defibrillators, Implantable Algorithms Arrhythmia Therapy Atrial Fibrillation Diagnosis Atrial Fibrillation Therapy Atrial Flutter Diagnosis Atrial Flutter Therapy Electrocardiography Electronics Tachycardia, Ventricular Diagnosis Tachycardia, Ventricular Therapy ab: ICDs are highly effective in preventing sudden cardiac death. However, inappropriate device shocks caused by false-positive diagnoses are estimated to happen in 20% of all patients. The need for implantable electrical devices to detect with precision arrhythmias requiring therapy has spawned a variety of proposals for better means of tack cardia identification. To address this problem, the augmented two-channel arrhythmia detection (A2GAD) algorithm, a real-time scheme utilizing timing and morphology from both the atrial and ventricular channels, is introduced. The algorithm uses rate detection as a first stage and augments this with morphological signal analysis in rhythms that confound the rate only diagnoses. The software executes in real-time (online), and has been tested on 60 passages of two-channel intracardiac signals. The following arrhythmias constituted the test set: 10 AF and/or atrial flutter; 15 SVT; 16 VT; 10 ventricular flutter or VF; 5 sinus tachycardia; and 4 cases of AF concurrent with VF. Results from 60 patient cases indicate 57 (95%) of 60 success rate for A2GAD. validating its potential for implementation in future implantable devices. pubtype: Academic Journal doctype: Journal Article ougenre: Article language: English refInfo: holdings: @attributes: islocal: N |
|---|