The performance of the probability density function in differentiating supraventricuiar from ventricular rhythms.
The ability of the probability density function (PDF) of an automatic implantable cardioverter defibrillator (AICD) to reject supraventricular arrhythmias being recognized as ventricular was evaluated in 12 patients who were treated with on AICD (Ventak P 1600). The PDF criterion was monitored via t...
| Publicado en: | Pacing & Clinical Electrophysiology Vol. 15; no. 5; pp. 726 - 731 |
|---|---|
| Autores principales: | , , |
| Formato: | Journal Article |
| Publicado: |
Wiley-Blackwell
May1992
|
| Acceso en línea: | Ver este registro en EBSCOhost |
| fields | @attributes: recordID: 1 pdfLink: plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106086976&site=ehost-live header: @attributes: shortDbName: ccm uiTerm: 106086976 longDbName: CINAHL Complete uiTag: AN controlInfo: bkinfo: dissinfo: jinfo: jid: 01478389 4F8 jtl: Pacing & Clinical Electrophysiology issn: 01478389 maglogo: Y pubinfo: dt: May1992 vid: 15 iid: 5 pid: 480 pub: Wiley-Blackwell place: Malden, Massachusetts artinfo: ui: 106086976 2009413090 NLM1382273 106086976 ppf: 726 ppct: 5 formats: fmt: @attributes: type: P tig: atl: The performance of the probability density function in differentiating supraventricuiar from ventricular rhythms. aug: au: Toivonen L Viitasalo M Järvinen A sug: subj: Cardioversion Equipment and Supplies Prostheses and Implants Tachycardia Therapy Tachycardia, Supraventricular Therapy Electrocardiography Exercise Test Female Male Middle Age Telemetry Ventricular Fibrillation Therapy Middle Aged: 45-64 years Female Male ab: The ability of the probability density function (PDF) of an automatic implantable cardioverter defibrillator (AICD) to reject supraventricular arrhythmias being recognized as ventricular was evaluated in 12 patients who were treated with on AICD (Ventak P 1600). The PDF criterion was monitored via telemetry with the sinus rate during exercise test. PDF was satisfied in seven patients at a rate of 75-144/min (mean 109/min), and not in the remaining five patients (mean rate 141/ min). PDF was fulfilled in five of ten patients at a lower heart rate than predicted by the duty cycle index, derived from the ventricular patch lead electrogram at the implantation. Thus PDF is often fulfilled already at a moderately elevated sinus rate, if used to prevent inadvertent AICD discharges during rapid supraventricular rhythms, its performance should be tested in the individual patient. pubtype: Academic Journal doctype: Journal Article ougenre: Article language: English refInfo: holdings: @attributes: islocal: N |
|---|