The performance of the probability density function in differentiating supraventricuiar from ventricular rhythms.

The ability of the probability density function (PDF) of an automatic implantable cardioverter defibrillator (AICD) to reject supraventricular arrhythmias being recognized as ventricular was evaluated in 12 patients who were treated with on AICD (Ventak P 1600). The PDF criterion was monitored via t...

Descripción completa

Detalles Bibliográficos
Publicado en:Pacing & Clinical Electrophysiology Vol. 15; no. 5; pp. 726 - 731
Autores principales: Toivonen L, Viitasalo M, Järvinen A
Formato: Journal Article
Publicado: Wiley-Blackwell May1992
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106086976&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 106086976
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        01478389
        4F8
      jtl: Pacing & Clinical Electrophysiology
      issn: 01478389
      maglogo: Y
    pubinfo:
      dt: May1992
      vid: 15
      iid: 5
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        106086976
        2009413090
        NLM1382273
        106086976
      ppf: 726
      ppct: 5
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: The performance of the probability density function in differentiating supraventricuiar from ventricular rhythms.
      aug:
        au:
          Toivonen L
          Viitasalo M
          Järvinen A
      sug:
        subj:
          Cardioversion Equipment and Supplies
          Prostheses and Implants
          Tachycardia Therapy
          Tachycardia, Supraventricular Therapy
          Electrocardiography
          Exercise Test
          Female
          Male
          Middle Age
          Telemetry
          Ventricular Fibrillation Therapy
          Middle Aged: 45-64 years
          Female
          Male
      ab: The ability of the probability density function (PDF) of an automatic implantable cardioverter defibrillator (AICD) to reject supraventricular arrhythmias being recognized as ventricular was evaluated in 12 patients who were treated with on AICD (Ventak P 1600). The PDF criterion was monitored via telemetry with the sinus rate during exercise test. PDF was satisfied in seven patients at a rate of 75-144/min (mean 109/min), and not in the remaining five patients (mean rate 141/ min). PDF was fulfilled in five of ten patients at a lower heart rate than predicted by the duty cycle index, derived from the ventricular patch lead electrogram at the implantation. Thus PDF is often fulfilled already at a moderately elevated sinus rate, if used to prevent inadvertent AICD discharges during rapid supraventricular rhythms, its performance should be tested in the individual patient.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N