Pitfalls of the concept of incremental specificity used in comparisons of dual chamber vt/vf detection algorithms.

The concepts of incremental specificity and incremental positive predictive accuracy (PPA) have been proposed to measure the success of dual chamber cardioverter defibrillator (ICD) algorithms for tachyarrhythmia detection in improving specificity while maintaining very high sensitivity to detection...

Full description

Bibliographic Details
Published in:Pacing & Clinical Electrophysiology Vol. 23; no. 7; pp. 1166 - 1171
Main Author: Malik M
Format: research Journal Article
Published: Wiley-Blackwell Jul2000
Online Access:View this record in EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106087417&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 106087417
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        01478389
        4F8
      jtl: Pacing & Clinical Electrophysiology
      issn: 01478389
      maglogo: Y
    pubinfo:
      dt: Jul2000
      vid: 23
      iid: 7
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        106087417
        2009414429
        10.1111/j.1540-8159.2000.tb00919.x
        NLM10914375
        106087417
      ppf: 1166
      ppct: 5
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Pitfalls of the concept of incremental specificity used in comparisons of dual chamber vt/vf detection algorithms.
      aug:
        au: Malik M
      sug:
        subj:
          Detection Algorithms
          Defibrillators, Implantable Statistics and Numerical Data
          Tachycardia, Ventricular Diagnosis
          Ventricular Fibrillation Diagnosis
          Models, Statistical
          Predictive Value of Tests
          Sensitivity and Specificity
          Tachycardia, Ventricular Therapy
          Ventricular Fibrillation Therapy
          Human
      ab: The concepts of incremental specificity and incremental positive predictive accuracy (PPA) have been proposed to measure the success of dual chamber cardioverter defibrillator (ICD) algorithms for tachyarrhythmia detection in improving specificity while maintaining very high sensitivity to detection of episodes of ventricular tachycardia/fibrillation (VT/VF). While dual chamber VT/VF detection algorithms differ substantially among different ICD manufacturers, they all operate as 'add-on' features to the single chamber elementary detection algorithms that are based on simple criteria of increased ventricular rate. The incremental specificity and PPA characterize the performance of the dual chamber detection operation in this 'add-on' mode, that is within a database of rhythm episodes all meet the simple rate-based criteria. A statistical model of hypothetical devices has been used to demonstrate that the concepts of incremental specificity and PPA are very dependent on the composition of the database used to evaluate a particular dual chamber ICD. Because some sinus tachycardia and supraventricular tachyarrhythmias with regular atrioventricular conduction are more easily discriminated from true VT/VF than other supraventricular tachyarrhythmias, the model shows that rather than the performance of the dual chamber detection functions, the major contributor to the incremental specificity may be the proportion between the 'easy' and 'difficult' supraventricular episodes. The algorithms used by different ICD manufacturers to detect tachyarrhythmias based on ventricular rate are known to differ substantially in the ability to differentiate true VT/VF from other tachyarrhythmias. Consequently, the databases of rhythms against which the different dual camber ICDs are tested are also different in composition of different types of supraventricular tachyarrhythmias. Therefore, the values of incremental specificity and PPA reported by different manufacturers do not have an equivalent meaning and do not offer a valid comparison of the true performance of different dual chamber ICDs.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N