Correction of sampler-to-sampler comparisons based on aerosol size distribution.

This article explains a simple method for correcting a sampler-to-sampler ratio for changes in size distribution by computing a bias factor that relates the measured ratio with a ratio determined from equations that describe the collection efficiency curves of the samplers while taking size distribu...

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of Occupational & Environmental Hygiene Vol. 4; no. 4; pp. 237 - 246
Autores principales: O'Shaughnessy PT, Lo J, Golla V, Nakatsu J, Tillery MI, Reynolds S
Formato: equations & formulas tables/charts Journal Article
Publicado: Taylor & Francis Ltd Apr2007
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106171402&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 106171402
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        15459624
        V1L
      jtl: Journal of Occupational & Environmental Hygiene
      issn: 15459624
      maglogo: Y
    pubinfo:
      dt: Apr2007
      vid: 4
      iid: 4
      pid: 377
      pub: Taylor & Francis Ltd
      place: Philadelphia, Pennsylvania
    artinfo:
      ui:
        106171402
        106171402
        2009540802
        10.1080/15459620701193533
        NLM17365494
        106171402
      ppf: 237
      ppct: 9
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Correction of sampler-to-sampler comparisons based on aerosol size distribution.
      aug:
        au:
          O'Shaughnessy PT
          Lo J
          Golla V
          Nakatsu J
          Tillery MI
          Reynolds S
        affil: The University of Iowa -- Occupational and Environmental Health, Iowa City, Iowa.
      sug:
        subj:
          Aerosols Analysis
          Air Pollutants, Occupational Analysis
          Environmental Monitoring Methods
          Occupational Exposure Analysis
          Aerosols
          Dust Analysis
          Equipment Design
          Particle Size
      ab: This article explains a simple method for correcting a sampler-to-sampler ratio for changes in size distribution by computing a bias factor that relates the measured ratio with a ratio determined from equations that describe the collection efficiency curves of the samplers while taking size distribution into account. Laboratory trials were conducted to determine whether the resulting bias factor is independent of aerosol size distribution. During these studies, a 3-piece cassette and respirable cyclone were compared with an inhalable sampler in both a still-air chamber and a moving-air chamber operated at 0.2 m/sec and 1.0 m/sec. An ISO test dust of various size fractions was generated to produce an aerosol with mass median aerodynamic diameter ranging from 1.4 mum to 10.1 mum. An organic dust consisting of ground grain material was also applied to the still-air chamber to demonstrate differences between dust types. Results showed that the bias value was significantly different between dust types for both the cyclone/ inhalable (p=0.001) and cassette/inhalable (p=0.033) comparisons but was not different between wind conditions for either comparison. All but one comparison had insignificant slopes when comparing the bias value with median diameter, indicating that the bias value could be used to correct for size distributions in most conditions. However, bias values determined when comparing the cyclone with the inhalable sampler in the still-air condition produced a positive slope for median diameters less than 4mum(p=0.008). Further research is needed to determine why the actual cyclone/inhalable ratio decreases relative to the expected ratio as the proportion of respirable particles increases. These results suggest that, for most conditions, the size-distribution compensation can be applied to sampler-to-sampler correlations provided that the original comparison was performed with the same dust type.
      pubtype: Academic Journal
      doctype:
        equations & formulas
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N