Determining the MTF of medical imaging displays using edge techniques.

The modulation transfer function (MTF) of a medical imaging display is typically determined by measuring its response to square waves (bar patterns), white noise, and/or line stimuli. However, square waves and white noise methods involve capture and analysis of multiple images and are thus quite ted...

Full description

Bibliographic Details
Published in:Journal of Digital Imaging Vol. 18; no. 4; pp. 296 - 311
Main Authors: Chawla A, Roehrig H, Rodriguez J, Fan J
Format: equations & formulas tables/charts Journal Article
Published: Springer Nature Dec2005
Online Access:View this record in EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106332428&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 106332428
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        08971889
        DOQ
      jtl: Journal of Digital Imaging
      issn: 08971889
      maglogo: N
    pubinfo:
      dt: Dec2005
      vid: 18
      iid: 4
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        106332428
        2009269867
        10.1007/s10278-005-6977-4
        NLM16132485
        106332428
      ppf: 296
      ppct: 15
      formats:
      tig:
        atl: Determining the MTF of medical imaging displays using edge techniques.
      aug:
        au:
          Chawla A
          Roehrig H
          Rodriguez J
          Fan J
        affil: Radiology Research Laboratory, University of Arizona, (Bldg. 211), 1609 N. Warren Avenue, Tucson, AZ 85724
      sug:
        subj:
          Data Display
          Computer Terminals
          Radiographic Image Enhancement Equipment and Supplies
          Mathematics
      ab: The modulation transfer function (MTF) of a medical imaging display is typically determined by measuring its response to square waves (bar patterns), white noise, and/or line stimuli. However, square waves and white noise methods involve capture and analysis of multiple images and are thus quite tedious. Measurement of the line-spread function (LSF) offers a good alternative. However, as previously reported, low-frequency response obtained from the LSF method is not as good as that obtained from measurement of edge-spread function (ESF). In this paper, we present two methods for evaluating the MTF of a medical imaging display from its ESF. High degree of accuracy in the higher frequency region (near the Nyquist frequency of the system) was achieved by reducing the noise. In the first method, which is a variant of the Gans' original method, the periodic raster noise is reduced by subtracting a shifted ESF from the ESF. The second method employs a low-pass differentiator (LPD). A novel near maximally flat LPD with the desired cut-off frequency was designed for this purpose. Noise reduction in both the methods was also achieved by averaging over large portions of the image data to form the ESF. Experimental results show that the MTF obtained by these methods is comparable to that obtained from the square wave response. Furthermore, the MTFs of rising and falling edges of a cathode ray tube (CRT) were measured. The results show that the rising and falling vertical MTFs are practically the same, whereas the rising horizontal MTF is poorer than the falling horizontal MTF in the midfrequency region.
      pubtype: Academic Journal
      doctype:
        equations & formulas
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N