Scapular muscle tests in subjects with shoulder pain and functional loss: reliability and construct validity.

BACKGROUND AND PURPOSE: Scapular muscle performance evaluated with a handheld dynamometer (HHD) has been investigated only in people without shoulder dysfunction for test-retest reliability of data obtained with a single scapular muscle test. The purpose of this study was to assess the reliability,...

Descripción completa

Detalles Bibliográficos
Publicado en:Physical Therapy Vol. 85; no. 11; pp. 1128 - 1139
Autores principales: Michener LA, Boardman ND, Pidcoe PE, Frith AM
Formato: pictorial research tables/charts Journal Article
Publicado: Oxford University Press / USA Nov2005
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106399623&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 106399623
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        00319023
        PTH
      jtl: Physical Therapy
      issn: 00319023
      maglogo: N
    pubinfo:
      dt: Nov2005
      vid: 85
      iid: 11
      pid: 10398
      pub: Oxford University Press / USA
    artinfo:
      ui:
        106399623
        106399623
        2009082817
        10.1093/ptj/85.11.1128
        NLM16253043
        106399623
      ppf: 1128
      ppct: 11
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Scapular muscle tests in subjects with shoulder pain and functional loss: reliability and construct validity.
      aug:
        au:
          Michener LA
          Boardman ND
          Pidcoe PE
          Frith AM
        affil: Assistant Professor, Department of Physical Therapy, Room 100, West Hospital Basement, Virginia Commonwealth University-Medical College of Virginia Campus, Richmond, VA 23298
      sug:
        subj:
          Shoulder Pain Diagnosis
          Muscle, Skeletal Physiopathology
          Physical Examination Methods
          Scapula
          Shoulder Joint Injuries
          Dynamometry
          Exercise Test, Muscular Methods
          Clinical Assessment Tools
          Electromyography
          Scales
          Isometric Contraction
          Range of Motion
          Shoulder Pain Etiology
          Validation Studies
          Intraclass Correlation Coefficient
          Descriptive Statistics
          Confidence Intervals
          Intrarater Reliability
          Analysis of Variance
          Repeated Measures
          Post Hoc Analysis
          Construct Validity
          Summated Rating Scaling
          Adult
          Middle Age
          Aged
          Female
          Male
          Funding Source
          Human
          Adult: 19-44 years
          Middle Aged: 45-64 years
          Aged: 65+ years
          Female
          Male
      ab: BACKGROUND AND PURPOSE: Scapular muscle performance evaluated with a handheld dynamometer (HHD) has been investigated only in people without shoulder dysfunction for test-retest reliability of data obtained with a single scapular muscle test. The purpose of this study was to assess the reliability, error, and validity of data obtained with an HHD for 4 scapular muscle tests in subjects with shoulder pain and functional loss. SUBJECTS AND METHODS: Subjects (N=40) with shoulder pain and functional loss were tested by measuring the kilograms applied with an HHD during 3 trials for muscle tests for the lower trapezius, upper trapezius, middle trapezius, and serratus anterior muscles. Concurrently, surface electromyography (sEMG) data were collected for the 4 muscles. The same procedures were performed 24 to 72 hours after the initial testing by the same tester. Muscle tests were performed 3 times, and the results were averaged for data analysis. RESULTS: Intraclass correlation coefficients for intratester reliability of measurements of isometric force obtained using an HHD ranged from .89 to .96. The standard error of the measure (90% confidence interval [CI]) ranged from 1.3 to 2.7 kg; the minimal detectable change (90% CI) ranged from 1.8 to 3.6 kg. Construct validity assessment, done by comparing the amounts of isometric muscle activity (sEMG) for each muscle across the 4 muscle tests, revealed that the muscle activity of the upper trapezius and lower trapezius muscles was highest during their respective tests. Conversely, the isometric muscle activity of the middle trapezius and serratus anterior muscles was not highest during their respective tests. DISCUSSION AND CONCLUSION: In people with shoulder pain and functional loss, the intrarater reliability and error over 1 to 3 days were established using an HHD for measurement of isometric force for the assessment of scapular muscle performance. Error values can be used to make decisions regarding individual patients. Construct validity was established for the lower and upper trapezius muscle tests; therefore, these tests are advocated for use. However, construct validity was not demonstrated for the serratus anterior and middle trapezius muscle tests as performed in this study. Further investigation of these muscle tests is warranted.
      pubtype: Academic Journal
      doctype:
        pictorial
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N