Compression-dependent differences in hearing aid gain between speech and nonspeech input signals.

Objective: A primary purpose of fitting hearing aids is to improve the audibility of speech; however, hearing aid gain is typically measured by using standardized nonspeech signals, e.g., swept pure tones, speech-weighted broadband noise, or modulated noise. When compression hearing aids are tested...

Descripción completa

Detalles Bibliográficos
Publicado en:Ear & Hearing (01960202) Vol. 26; no. 4; pp. 409 - 423
Autores principales: Henning RW, Bentler R, Henning, Rebecca Warner, Bentler, Ruth
Formato: research tables/charts Journal Article
Publicado: Lippincott Williams & Wilkins Aug2005
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106536581&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 106536581
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        01960202
        IM7
      jtl: Ear & Hearing (01960202)
      issn: 01960202
      maglogo: N
    pubinfo:
      dt: Aug2005
      vid: 26
      iid: 4
      pid: 433
      pub: Lippincott Williams & Wilkins
      place: Baltimore, Maryland
    artinfo:
      ui:
        106536581
        106536581
        NLM16079635
        2009014417
        10.1097/00003446-200508000-00004
        NLM16079635
        106536581
      ppf: 409
      ppct: 14
      formats:
      tig:
        atl: Compression-dependent differences in hearing aid gain between speech and nonspeech input signals.
      aug:
        au:
          Henning RW
          Bentler R
          Henning, Rebecca Warner
          Bentler, Ruth
        affil: University of Iowa, Iowa City, IA, USA
      sug:
        subj:
          Hearing Aids
          Speech Perception
          Audiometry, Pure-Tone
          Multiple Linear Regression
          Quantitative Studies
          Signal Processing, Computer Assisted
          Spectral Analysis
          Speech Discrimination Tests
          Test-Retest Reliability
          Human
      ab: Objective: A primary purpose of fitting hearing aids is to improve the audibility of speech; however, hearing aid gain is typically measured by using standardized nonspeech signals, e.g., swept pure tones, speech-weighted broadband noise, or modulated noise. When compression hearing aids are tested with these nonspeech input signals, the measured gain can be substantially different than if a real speech input signal were used. The purpose of this study was to systematically evaluate the effects of release time, compression ratio, and number of compression channels, as well as interactions of these parameters, on the gain difference between several common nonspeech hearing aid test signals and speech. It was hypothesized that the difference in hearing aid gain between static nonspeech signals and speech would increase as release time, compression ratio, and number of channels increased.Design: Speech and several common nonspeech hearing aid test signals, matched at overall root-mean-square levels corresponding to average (65 dB SPL) and loud (80 dB SPL) conversational speech, were input into a master hearing aid circuit, and the gain of the circuit was measured in one-third octave bands. The hearing aid was programmed as a moderate-gain (23 dB) wide dynamic range compression instrument with a compression threshold of 50 dB SPL. The release time, compression ratio, and number of compression channels of the circuit were systematically adjusted by programming software. The one-third octave band gain differences between the nonspeech signals and speech were measured for all combinations of the compression settings. Multiple regression analysis was used to evaluate the effects of each compression parameter, and interactions of the parameters, on the gain difference between each nonspeech signal and speech.Results: One-third octave band gain differences between nonspeech and speech signals (calculated as nonspeech signal minus speech signal) ranged from -3.1 to 10.4 dB, depending on frequency, nonspeech test signal, and input signal level. In most cases, the compression parameters accounted for more than 70% of the variance in gain differences between the speech and nonspeech signals. At an input level of 65 dB, increases in the release time and compression ratio led to an increase in the gain difference between most nonspeech signals and speech at most frequencies. Increases in the number of channels caused an increase in the gain difference when the spectra of the nonspeech signals differed from the speech spectrum. The effects of release time and number of channels increased as the compression ratio increased. At an 80 dB input level, increasing the compression ratio led to a decrease in the gain difference between the nonspeech signals and speech. Release time and number of channels had little to no effect at the higher input level.Conclusions: The compression parameters of release time, compression ratio, and number of compression channels explain most of the variance in differences in hearing aid gain between nonspeech and speech signals. It may be cumbersome, however, to quantitatively define this relationship for all hearing aid circuits. It is therefore recommended that hearing aid "use" gain or output be measured with a real speech signal. If a nonspeech signal must be used, then it should have spectral and temporal properties that are similar to speech.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N