Optimization of cardiac resynchronization therapy by continuous hemodynamic monitoring: a case report.
We report the case of a 55-year-old male patient with severe congestive heart failure in whom both a hemodynamic monitor and a biventricular pacemaker were implanted. The potential usefulness of the monitor to optimize AV delay and heart rate was prospectively evaluated. The AV delay associated with...
| Published in: | Journal of Cardiovascular Electrophysiology Vol. 15; no. 1; pp. 94 - 97 |
|---|---|
| Main Authors: | , , , |
| Format: | research tables/charts Journal Article |
| Published: |
Wiley-Blackwell
Jan2004
|
| Online Access: | View this record in EBSCOhost |
| fields | @attributes: recordID: 1 pdfLink: plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106673455&site=ehost-live header: @attributes: shortDbName: ccm uiTerm: 106673455 longDbName: CINAHL Complete uiTag: AN controlInfo: bkinfo: dissinfo: jinfo: jid: 10453873 GSB jtl: Journal of Cardiovascular Electrophysiology issn: 10453873 maglogo: Y pubinfo: dt: Jan2004 vid: 15 iid: 1 pid: 480 pub: Wiley-Blackwell place: Malden, Massachusetts artinfo: ui: 106673455 2004204069 10.1046/j.1540-8167.2004.03208.x NLM15028081 106673455 ppf: 94 ppct: 3 formats: fmt: @attributes: type: P tig: atl: Optimization of cardiac resynchronization therapy by continuous hemodynamic monitoring: a case report. aug: au: Braunschweig F Kjellström B Gadler F Linde C affil: Department of Cardiology, Karolinska Hospital, 171 76 Stockholm, Sweden; frieder.braunschweig@ks.se sug: subj: Cardiac Pacing, Artificial Methods Heart Failure Therapy Hemodynamics Monitoring, Physiologic Utilization Heart Rate Male Middle Age Human Middle Aged: 45-64 years Male ab: We report the case of a 55-year-old male patient with severe congestive heart failure in whom both a hemodynamic monitor and a biventricular pacemaker were implanted. The potential usefulness of the monitor to optimize AV delay and heart rate was prospectively evaluated. The AV delay associated with the lowest filling pressures recorded by the monitor was similar to the optimal AV delay as determined by standard echocardiography. Heart rates >70 beats/min acutely improved hemodynamics but were not tolerated when programmed chronically. This case illustrates that continuous hemodynamic monitoring may offer a useful tool for device tuning and treatment monitoring in cardiac resynchronization therapy. pubtype: Academic Journal doctype: research tables/charts Journal Article ougenre: Article language: English refInfo: holdings: @attributes: islocal: N |
|---|